Fatigue of Micro Molded Materials - Aluminum Bronze and Yttria Stabilized Zirconia
Custom built setups were developed to investigate micro samples during quasistatic and cyclic testing in tension, compression and bending. Micro molded CuAl10Ni5Fe4-samples showed similar fatigue behavior compared to macroscopic samples due to both the sample size and microstructure being scaled dow...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2014
|
Series: | Schriftenreihe des Instituts für Angewandte Materialien, Karlsruher Institut für Technologie
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_47440 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2014 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000043832 | ||
020 | |a 9783731502937 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000043832 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Kennerknecht, Tobias |4 auth | |
245 | 1 | 0 | |a Fatigue of Micro Molded Materials - Aluminum Bronze and Yttria Stabilized Zirconia |
260 | |b KIT Scientific Publishing |c 2014 | ||
300 | |a 1 electronic resource (XII, 255 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Schriftenreihe des Instituts für Angewandte Materialien, Karlsruher Institut für Technologie | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a Custom built setups were developed to investigate micro samples during quasistatic and cyclic testing in tension, compression and bending. Micro molded CuAl10Ni5Fe4-samples showed similar fatigue behavior compared to macroscopic samples due to both the sample size and microstructure being scaled down with the manufacturing process. Results from cyclic three-point bending tests on micro molded 3Y-TZP suggested that a minimum crack extension is necessary to develop cyclically degradable shielding. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-sa/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-sa/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a Ermüdung Mikroguss Aluminiumbronze Zirkonoxid Apparaturresonance custom-built setup microstructure 3Y-TZP | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783731502937 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/47440 |7 0 |z DOAB: description of the publication |