Formation of Intracardiac Electrograms under Physiological and Pathological Conditions

This work presents methods to advance electrophysiological simulations of intracardiac electrograms (IEGM). An experimental setup is introduced, which combines electrical measurements of extracellular potentials with a method for optical acquisition of the transmembrane voltage in-vitro. Thereby, in...

Full description

Saved in:
Bibliographic Details
Main Author: Keller, Matthias (auth)
Format: Electronic Book Chapter
Language:English
Published: KIT Scientific Publishing 2014
Series:Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering
Subjects:
Online Access:DOAB: download the publication
DOAB: description of the publication
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000naaaa2200000uu 4500
001 doab_20_500_12854_47895
005 20210211
003 oapen
006 m o d
007 cr|mn|---annan
008 20210211s2014 xx |||||o ||| 0|eng d
020 |a KSP/1000041272 
020 |a 9783731502289 
040 |a oapen  |c oapen 
024 7 |a 10.5445/KSP/1000041272  |c doi 
041 0 |a eng 
042 |a dc 
072 7 |a TB  |2 bicssc 
100 1 |a Keller, Matthias  |4 auth 
245 1 0 |a Formation of Intracardiac Electrograms under Physiological and Pathological Conditions 
260 |b KIT Scientific Publishing  |c 2014 
300 |a 1 electronic resource (X, 238 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a This work presents methods to advance electrophysiological simulations of intracardiac electrograms (IEGM). An experimental setup is introduced, which combines electrical measurements of extracellular potentials with a method for optical acquisition of the transmembrane voltage in-vitro. Thereby, intracardiac electrograms can be recorded under defined conditions. Using experimental and clinical signals, detailed simulations of IEGMs are parametrized, which can support clinical diagnosis. 
540 |a Creative Commons  |f https://creativecommons.org/licenses/by-sa/4.0/  |2 cc  |4 https://creativecommons.org/licenses/by-sa/4.0/ 
546 |a English 
650 7 |a Technology: general issues  |2 bicssc 
653 |a catheter 
653 |a Simulation 
653 |a experiment 
653 |a signal processing 
653 |a Experiment 
653 |a simulation 
653 |a Herz 
653 |a Katheter 
653 |a Signalverarbeitungheart 
856 4 0 |a www.oapen.org  |u https://www.ksp.kit.edu/9783731502289  |7 0  |z DOAB: download the publication 
856 4 0 |a www.oapen.org  |u https://directory.doabooks.org/handle/20.500.12854/47895  |7 0  |z DOAB: description of the publication