Formation of Intracardiac Electrograms under Physiological and Pathological Conditions
This work presents methods to advance electrophysiological simulations of intracardiac electrograms (IEGM). An experimental setup is introduced, which combines electrical measurements of extracellular potentials with a method for optical acquisition of the transmembrane voltage in-vitro. Thereby, in...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2014
|
Series: | Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_47895 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2014 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000041272 | ||
020 | |a 9783731502289 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000041272 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Keller, Matthias |4 auth | |
245 | 1 | 0 | |a Formation of Intracardiac Electrograms under Physiological and Pathological Conditions |
260 | |b KIT Scientific Publishing |c 2014 | ||
300 | |a 1 electronic resource (X, 238 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a This work presents methods to advance electrophysiological simulations of intracardiac electrograms (IEGM). An experimental setup is introduced, which combines electrical measurements of extracellular potentials with a method for optical acquisition of the transmembrane voltage in-vitro. Thereby, intracardiac electrograms can be recorded under defined conditions. Using experimental and clinical signals, detailed simulations of IEGMs are parametrized, which can support clinical diagnosis. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-sa/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-sa/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a catheter | ||
653 | |a Simulation | ||
653 | |a experiment | ||
653 | |a signal processing | ||
653 | |a Experiment | ||
653 | |a simulation | ||
653 | |a Herz | ||
653 | |a Katheter | ||
653 | |a Signalverarbeitungheart | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783731502289 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/47895 |7 0 |z DOAB: description of the publication |