Magnetic Resonance Imaging on Patients with Implanted Cardiac Pacemakers
The aim of this work was to identify the patterns that can induce heating around implanted cardiac pacemakers during MRI and to develop strategies to counteract them. Two approaches were taken: computer simulations of the occurring electromagnetic field distributions and in-vitro experiments using p...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2011
|
Series: | Karlsruhe transactions on biomedical engineering / Ed.: Universität Karlsruhe (TH) / Institute of Biomedical Engineering
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_52567 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2011 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000021187 | ||
020 | |a 9783866446106 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000021187 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Seitz, Sebastian |4 auth | |
245 | 1 | 0 | |a Magnetic Resonance Imaging on Patients with Implanted Cardiac Pacemakers |
260 | |b KIT Scientific Publishing |c 2011 | ||
300 | |a 1 electronic resource (156 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Karlsruhe transactions on biomedical engineering / Ed.: Universität Karlsruhe (TH) / Institute of Biomedical Engineering | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a The aim of this work was to identify the patterns that can induce heating around implanted cardiac pacemakers during MRI and to develop strategies to counteract them. Two approaches were taken: computer simulations of the occurring electromagnetic field distributions and in-vitro experiments using phantoms in real MRI devices, both for conventional bore-hole and new open MRI systems. Using the open MRI, the observed heating could be reduced significantly. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-nc-nd/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a pacemaker | ||
653 | |a MRI | ||
653 | |a numerical field calculation | ||
653 | |a biomedical engineering | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783866446106 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/52567 |7 0 |z DOAB: description of the publication |