Modelling the human cardiac fluid mechanics

We present a virtual heart model simulating the flow in the left human ventricle and in the aorta. Because of the lack of in vivo structure data of the human ventricle, the active ventricle movement is given by a time-dependent ventricle model that is derived from in vivo image data of a nuclear spi...

Full description

Saved in:
Bibliographic Details
Main Author: Oertel, Herbert (auth)
Format: Electronic Book Chapter
Language:English
Published: KIT Scientific Publishing 2005
Subjects:
Online Access:DOAB: download the publication
DOAB: description of the publication
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000naaaa2200000uu 4500
001 doab_20_500_12854_53747
005 20210211
003 oapen
006 m o d
007 cr|mn|---annan
008 20210211s2005 xx |||||o ||| 0|eng d
020 |a KSP/1000003551 
020 |a 3937300821 
040 |a oapen  |c oapen 
024 7 |a 10.5445/KSP/1000003551  |c doi 
041 0 |a eng 
042 |a dc 
072 7 |a TB  |2 bicssc 
100 1 |a Oertel, Herbert  |4 auth 
245 1 0 |a Modelling the human cardiac fluid mechanics 
260 |b KIT Scientific Publishing  |c 2005 
300 |a 1 electronic resource (49 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a We present a virtual heart model simulating the flow in the left human ventricle and in the aorta. Because of the lack of in vivo structure data of the human ventricle, the active ventricle movement is given by a time-dependent ventricle model that is derived from in vivo image data of a nuclear spin MRT tomograph of a healthy human heart. The passive part of the virtual heart model consists of a model aorta and vena cava, and of heart valves. As the movement is due to the flow in the inactive region of the heart, a coupling of flow and structure is necessary in the model to take into account the deviation of the aorta and the closing and opening of the heart valves. The flow calculation is performed with a finite volume method, while the structure of the aorta is calculated using the finite element method. The flow resistance of the time simulation in the body is taken into account with a circulation model. In the outlook of the article, we show how the virtual heart model can be used to predict flow losses due to pathological ventricle contraction defects in an unhealthy human heart. 
540 |a Creative Commons  |f https://creativecommons.org/licenses/by-nc-nd/4.0/  |2 cc  |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ 
546 |a English 
650 7 |a Technology: general issues  |2 bicssc 
653 |a pathological ventricle defects 
653 |a Computer Fluid Dynamics 
653 |a in vivo 
653 |a left human ventricle 
653 |a MRI tomography 
856 4 0 |a www.oapen.org  |u https://www.ksp.kit.edu/3937300821  |7 0  |z DOAB: download the publication 
856 4 0 |a www.oapen.org  |u https://directory.doabooks.org/handle/20.500.12854/53747  |7 0  |z DOAB: description of the publication