Near Infrared Laser Sensor System for In-Line Detection of Conversion in UV-Cured Polymer Coatings

The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process.The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yazar: Bach, Mathias (auth)
Materyal Türü: Elektronik Kitap Bölümü
Dil:İngilizce
Baskı/Yayın Bilgisi: KIT Scientific Publishing 2012
Konular:
Online Erişim:DOAB: download the publication
DOAB: description of the publication
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
Diğer Bilgiler
Özet:The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process.The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the sensor to discriminate between polymerized and unpolymerized coatings on metal substrates down to a coating thickness of less than 16µm is demonstrated and and proved by reference measurements.
Fiziksel Özellikler:1 electronic resource (VII, 129 p. p.)
ISBN:KSP/1000027435
9783866448391
Erişim:Open Access