Near Infrared Laser Sensor System for In-Line Detection of Conversion in UV-Cured Polymer Coatings
The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process.The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2012
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_54387 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2012 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000027435 | ||
020 | |a 9783866448391 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000027435 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Bach, Mathias |4 auth | |
245 | 1 | 0 | |a Near Infrared Laser Sensor System for In-Line Detection of Conversion in UV-Cured Polymer Coatings |
260 | |b KIT Scientific Publishing |c 2012 | ||
300 | |a 1 electronic resource (VII, 129 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process.The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the sensor to discriminate between polymerized and unpolymerized coatings on metal substrates down to a coating thickness of less than 16µm is demonstrated and and proved by reference measurements. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-nc-nd/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a acrylate | ||
653 | |a photopolymerization | ||
653 | |a in-line monioring | ||
653 | |a UV-coatings | ||
653 | |a 1620 nm overtone absorption | ||
653 | |a conversion monitoring | ||
653 | |a IR-spectroscopy | ||
653 | |a coating thickness | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783866448391 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/54387 |7 0 |z DOAB: description of the publication |