Numerical efficiency calibration of in vivo measurement systems : Monte Carlo simulations of in vivo measurement scenarios for the detection of incorporated radionuclides, including validation, analysis of efficiency-sensitive parameters and customized anthropomorphic voxel models
Monte Carlo radiation transport codes were used with virtual models of in vivo measurement equipment. Software was coded to handle memory intensive anthropomorphic voxel models for simulation of measurement scenarios. Tools, methods and models have been validated. Various parameters have been invest...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2010
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_54916 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2010 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000017470 | ||
020 | |a 9783866445093 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000017470 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Hegenbart, Lars |4 auth | |
245 | 1 | 0 | |a Numerical efficiency calibration of in vivo measurement systems : Monte Carlo simulations of in vivo measurement scenarios for the detection of incorporated radionuclides, including validation, analysis of efficiency-sensitive parameters and customized anthropomorphic voxel models |
260 | |b KIT Scientific Publishing |c 2010 | ||
300 | |a 1 electronic resource (X, 237 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a Monte Carlo radiation transport codes were used with virtual models of in vivo measurement equipment. Software was coded to handle memory intensive anthropomorphic voxel models for simulation of measurement scenarios. Tools, methods and models have been validated. Various parameters have been investigated for their sensitivity. Methods based on image registration techniques have been developed to transform existing human models to match with an individual test person. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-nc-nd/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a voxel model | ||
653 | |a efficiency calibration | ||
653 | |a in vivo measurement | ||
653 | |a Monte Carlo radiation transport simulations | ||
653 | |a incorporated radionuclides | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783866445093 |7 0 |z DOAB: download the publication |