SAR Prediction and SAR Management for Parallel Transmit MRI
Parallel transmission enables control of the RF field in high-field Magnetic Resonance Imaging (MRI). However, the approach has also caused concerns about the specific absorption rate (SAR) in the patient body. The present work provides new concepts for SAR prediction. A novel approach for generatin...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2012
|
Series: | Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_58850 | ||
005 | 20210212 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210212s2012 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000025607 | ||
020 | |a 9783866448001 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000025607 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Homann, Hanno |4 auth | |
245 | 1 | 0 | |a SAR Prediction and SAR Management for Parallel Transmit MRI |
260 | |b KIT Scientific Publishing |c 2012 | ||
300 | |a 1 electronic resource (VIII, 124 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a Parallel transmission enables control of the RF field in high-field Magnetic Resonance Imaging (MRI). However, the approach has also caused concerns about the specific absorption rate (SAR) in the patient body. The present work provides new concepts for SAR prediction. A novel approach for generating human body models is proposed, based on a water-fat separated MRI pre-scan. Furthermore, this work explores various approaches for SAR reduction. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-nc-nd/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a patient safety | ||
653 | |a radio frequency | ||
653 | |a Magnetic Resonance Imaging (MRI) | ||
653 | |a parallel transmission | ||
653 | |a Specific Absorption Rate (SAR) | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783866448001 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/58850 |7 0 |z DOAB: description of the publication |