Tunable Diode-Laser Absorption Spectroscopy for Trace-Gas Measurements with High Sensitivity and Low Drift

This book discusses the mechanical and opto-electronic design of laser spectrometers for measuring two very important atmospheric gases, namely water vapor and its isotopic ratios, and formaldehyde. For measuring water vapor, shot-noise limited sensitivity has been achieved by a careful choice of sy...

Full description

Saved in:
Bibliographic Details
Main Author: Dyroff, Christoph (auth)
Format: Electronic Book Chapter
Language:English
Published: KIT Scientific Publishing 2009
Series:Karlsruhe Series in Photonics & Communications / Universität Karlsruhe (TH), Institute of High-Frequency and Quantum Electronics (IHQ)
Subjects:
Online Access:DOAB: download the publication
DOAB: description of the publication
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000naaaa2200000uu 4500
001 doab_20_500_12854_61398
005 20210212
003 oapen
006 m o d
007 cr|mn|---annan
008 20210212s2009 xx |||||o ||| 0|eng d
020 |a KSP/1000010030 
020 |a 9783866443280 
040 |a oapen  |c oapen 
024 7 |a 10.5445/KSP/1000010030  |c doi 
041 0 |a eng 
042 |a dc 
072 7 |a TB  |2 bicssc 
100 1 |a Dyroff, Christoph  |4 auth 
245 1 0 |a Tunable Diode-Laser Absorption Spectroscopy for Trace-Gas Measurements with High Sensitivity and Low Drift 
260 |b KIT Scientific Publishing  |c 2009 
300 |a 1 electronic resource (142 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a Karlsruhe Series in Photonics & Communications / Universität Karlsruhe (TH), Institute of High-Frequency and Quantum Electronics (IHQ) 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a This book discusses the mechanical and opto-electronic design of laser spectrometers for measuring two very important atmospheric gases, namely water vapor and its isotopic ratios, and formaldehyde. For measuring water vapor, shot-noise limited sensitivity has been achieved by a careful choice of system components and data processing. For measuring formaldehyde, a selective sample modulation exploiting the Stark effect has been used to greatly improve the sensitivity. 
540 |a Creative Commons  |f https://creativecommons.org/licenses/by-nc-nd/4.0/  |2 cc  |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ 
546 |a English 
650 7 |a Technology: general issues  |2 bicssc 
653 |a Water Isotopic Ratio 
653 |a Diode Laser 
653 |a Laser Spectroscopy 
653 |a Formaldehyde 
653 |a Stark Effect 
856 4 0 |a www.oapen.org  |u https://www.ksp.kit.edu/9783866443280  |7 0  |z DOAB: download the publication 
856 4 0 |a www.oapen.org  |u https://directory.doabooks.org/handle/20.500.12854/61398  |7 0  |z DOAB: description of the publication