Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung
X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Published: |
KIT Scientific Publishing
2017
|
Series: | Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_61953 | ||
005 | 20210212 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210212s2017 xx |||||o ||| 0|deu d | ||
020 | |a KSP/1000075852 | ||
020 | |a 9783731507314 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000075852 |c doi | |
041 | 0 | |a deu | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Schröter, Tobias Jörg |4 auth | |
245 | 1 | 0 | |a Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung |
260 | |b KIT Scientific Publishing |c 2017 | ||
300 | |a 1 electronic resource (XII, 185 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to a few centimeters in the diagonal (e.g. 10 cm). In this work possibilities to enlarge the area of X-ray gratings, as they are required for the Talbot-Lau Interferometry, were developed and analyzed. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-sa/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-sa/4.0/ | ||
546 | |a German | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a Kacheln | ||
653 | |a Talbot-Lau Interferometry | ||
653 | |a Röntgengitter | ||
653 | |a Talbot-Lau Interferometrie | ||
653 | |a Röntgenbildgebung | ||
653 | |a LIGA-Technik | ||
653 | |a tiling | ||
653 | |a LIGA-technology | ||
653 | |a X-ray gratings | ||
653 | |a X-ray imaging | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783731507314 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/61953 |7 0 |z DOAB: description of the publication |