Chapter Tidal Turbine Generators

Recently, tidal stream turbines have become a preferable mode of harvesting tidal energy. The main issue for low utilization of tidal energy is the high levelized cost of energy (LCoE) from tidal stream turbines. A major reason for this is the high operation and maintenance costs for submerged insta...

Full description

Saved in:
Bibliographic Details
Main Author: Polinder, Henk (auth)
Other Authors: Wani, Faisal (auth), Dong, Jianning (auth)
Format: Electronic Book Chapter
Language:English
Published: InTechOpen 2020
Subjects:
Online Access:DOAB: download the publication
DOAB: description of the publication
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000naaaa2200000uu 4500
001 doab_20_500_12854_70185
003 oapen
006 m o d
007 cr|mn|---annan
008 ||||||||s2020 xx |||||o ||| 0|eng d
020 |a intechopen.90433 
040 |a oapen  |c oapen 
024 7 |a 10.5772/intechopen.90433  |c doi 
041 0 |a eng 
042 |a dc 
072 7 |a TBC  |2 bicssc 
100 1 |a Polinder, Henk  |4 auth 
700 1 |a Wani, Faisal  |4 auth 
700 1 |a Dong, Jianning  |4 auth 
245 1 0 |a Chapter Tidal Turbine Generators 
260 |b InTechOpen  |c 2020 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a Recently, tidal stream turbines have become a preferable mode of harvesting tidal energy. The main issue for low utilization of tidal energy is the high levelized cost of energy (LCoE) from tidal stream turbines. A major reason for this is the high operation and maintenance costs for submerged installations. A possible way of minimizing the LCoE and improving the availability is to use a flooded (or a wetgap) generator rather than a conventional airgap generator. Inside flooded generators, the gap between the stator and rotor is filled with the seawater. This architecture has the potential to improve cooling and reduce reliance on ancillary systems (e.g., bilge system), thereby improving reliability. The chapter begins with a brief description of the generator systems used in current tidal stream turbines. The focus of the chapter is, however, to give a basic insight into the design aspects of the flooded generators, and compares it with the currently used sealed airgap generators in tidal turbine systems. 
540 |a Creative Commons  |f https://creativecommons.org/licenses/by/3.0/  |2 cc  |4 https://creativecommons.org/licenses/by/3.0/ 
546 |a English 
650 7 |a Engineering: general  |2 bicssc 
653 |a tidal stream turbines, permanent magnet generators, flooded generators, corrosion, rotor-can 
773 1 0 |7 nnaa 
856 4 0 |a www.oapen.org  |u https://library.oapen.org/bitstream/20.500.12657/49375/1/70560.pdf  |7 0  |z DOAB: download the publication 
856 4 0 |a www.oapen.org  |u https://library.oapen.org/bitstream/20.500.12657/49375/1/70560.pdf  |7 0  |z DOAB: download the publication 
856 4 0 |a www.oapen.org  |u https://directory.doabooks.org/handle/20.500.12854/70185  |7 0  |z DOAB: description of the publication