Investigation of polymerization properties of 3D printable biocompatible polymers

The development of digital technology is more and more meaningful on the area of dentistry. There are many factors that influence the accuracy of 3D printing among others composition of polymers for printing, that determine the polymerization parameters such as polymerization shrinkage (PS) and degr...

Full description

Saved in:
Bibliographic Details
Main Authors: Melinda Szalóki (Author), Hamid Javadi (Author), Sara Khandan (Author), Adelina Stephanie Youssef (Author), József Gáll (Author), Csaba Hegedűs (Author)
Format: Book
Published: Hungarian Dental Association, 2019-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_017cef948a8745b9af1625cb6ac76bde
042 |a dc 
100 1 0 |a Melinda Szalóki  |e author 
700 1 0 |a Hamid Javadi  |e author 
700 1 0 |a Sara Khandan  |e author 
700 1 0 |a Adelina Stephanie Youssef  |e author 
700 1 0 |a József Gáll  |e author 
700 1 0 |a Csaba Hegedűs  |e author 
245 0 0 |a Investigation of polymerization properties of 3D printable biocompatible polymers 
260 |b Hungarian Dental Association,   |c 2019-10-01T00:00:00Z. 
500 |a 2498-8170 
500 |a 10.33891/FSZ.112.3.70-76 
520 |a The development of digital technology is more and more meaningful on the area of dentistry. There are many factors that influence the accuracy of 3D printing among others composition of polymers for printing, that determine the polymerization parameters such as polymerization shrinkage (PS) and degree of conversion (DC). These factors have an important role in the postpolymerization process that have an effect on accuracy of 3D printing and torsional parameters. Aim of this study was to analyse the polymerization parameters (PS and DC) of MED610 and MED620 (Stratasys, USA) during five-day period after the printing. Based on our measurements it was found that PS values were increased from 7,9433 vol% to 8,1704 vol% at MED610 and from 7,0619 vol% to 7,5598 vol% at MED620 during the five days period. The DC values were between 90,182 and 99,9433% and showed the maximum at third day. The polymerization parameters showed significant differences between the first day and fifth day measurements. Based on data of this study it can established that distortion error of MED610 is 22,71 μm and 49,79 μm at MED620 from polymerization shrinkage regarding a 10 cm length printed object. This values do not mean a distortion relative to the parameters of the real specimen, since in it e.g. scanners, and different design software of algorithms can still play a role. The clinical relevance is that the postpolymerization can cause distortion that effect is more relevant than has effect on the accuracy of the printed object to influence the dental application of these materials. 
546 |a EN 
546 |a HU 
690 |a med610 
690 |a med620 
690 |a 3d printable biocompatible polymer 
690 |a polymerization shrinkage 
690 |a degree of conversion 
690 |a postpolymerization 
690 |a polyjet 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Fogorvosi Szemle, Vol 112, Iss 3, Pp 70-76 (2019) 
787 0 |n https://ojs.mtak.hu/index.php/fogorv-szemle/article/view/2173 
787 0 |n https://doaj.org/toc/2498-8170 
856 4 1 |u https://doaj.org/article/017cef948a8745b9af1625cb6ac76bde  |z Connect to this object online.