Evaluation of force systems generated by Memory Titanol® springs with different preactivation bends

ABSTRACT Objective: This study evaluated the force system generated by the Memory Titanol® spring (MTS) with different preactivation bends using an orthodontic force tester (OFT). Methods: Three preactivations were tested using a 0.017 × 0.022-in stainless steel (SS) wire and a 0.018 × 0.025-in NiTi...

Full description

Saved in:
Bibliographic Details
Main Authors: Henrique Barcelos BRANDÃO (Author), Jonas BIANCHI (Author), Lucas Arrais de CAMPOS (Author), Alyssa Schiavon GANDINI (Author), Luiz Gonzaga GANDINI JUNIOR (Author)
Format: Book
Published: Dental Press Editora, 2024-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_030ff95d2a504fdd888f8cf3ffd25922
042 |a dc 
100 1 0 |a Henrique Barcelos BRANDÃO  |e author 
700 1 0 |a Jonas BIANCHI  |e author 
700 1 0 |a Lucas Arrais de CAMPOS  |e author 
700 1 0 |a Alyssa Schiavon GANDINI  |e author 
700 1 0 |a Luiz Gonzaga GANDINI JUNIOR  |e author 
245 0 0 |a Evaluation of force systems generated by Memory Titanol® springs with different preactivation bends 
260 |b Dental Press Editora,   |c 2024-10-01T00:00:00Z. 
500 |a 2177-6709 
500 |a 10.1590/2177-6709.29.5.e242430.oar 
520 |a ABSTRACT Objective: This study evaluated the force system generated by the Memory Titanol® spring (MTS) with different preactivation bends using an orthodontic force tester (OFT). Methods: Three preactivations were tested using a 0.017 × 0.022-in stainless steel (SS) wire and a 0.018 × 0.025-in NiTi segment, with an activation of 30º in the posterior segment (β), with 0º (Group 1 [G1]), 45º (Group 2 [G2]), and 60º (Group 3 [G3]) in the anterior segment (α). Results: The molars showed extrusion values of −1.33 N for G1 and −0.78 N for G2, and an intrusion value of 0.33 N for G3. The force in the premolars was intrusive with a variation of 1.34 N for G1 and 0.77 N for G2; and extrusive with a variation of −0.31 N for G3. Regarding the upright moment (Ty) of the molar, a distal moment was observed with values of 53.45 N.mm for G1 and 19.87 N.mm for G2, while G3 presented a mesial moment of −6.23 N.mm. G1, G2, and G3 all exhibited distal premolar moments (Ty) of 3.58, 2.45, and 0.68 N.mm, respectively. Conclusions: The tested preactivations exerted an extrusive force in G1 and G2 and an intrusive force in G3 during molar vertical movement. The premolar region in G1 and G2 showed intrusive force and distal moment. 
546 |a EN 
546 |a PT 
690 |a Orthodontics, corrective 
690 |a Biomechanical phenomena 
690 |a Tooth movement techniques 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Press Journal of Orthodontics, Vol 29, Iss 5 (2024) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512024000500300&lng=en&tlng=en 
787 0 |n http://www.scielo.br/pdf/dpjo/v29n5/2177-6709-dpjo-29-05-e242430.pdf 
787 0 |n https://doaj.org/toc/2177-6709 
856 4 1 |u https://doaj.org/article/030ff95d2a504fdd888f8cf3ffd25922  |z Connect to this object online.