Correlation between margin fit and microleakage in complete crowns cemented with three luting agents

Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premola...

Full description

Saved in:
Bibliographic Details
Main Authors: Paulo Henrique Orlato Rossetti (Author), Accacio Lins do Valle (Author), Ricardo Marins de Carvalho (Author), Mario Fernando De Goes (Author), Luiz Fernando Pegoraro (Author)
Format: Book
Published: University of São Paulo, 2008-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_04a3cc59b97e45b281a46efbe3c76ac1
042 |a dc 
100 1 0 |a Paulo Henrique Orlato Rossetti  |e author 
700 1 0 |a Accacio Lins do Valle  |e author 
700 1 0 |a Ricardo Marins de Carvalho  |e author 
700 1 0 |a Mario Fernando De Goes  |e author 
700 1 0 |a Luiz Fernando Pegoraro  |e author 
245 0 0 |a Correlation between margin fit and microleakage in complete crowns cemented with three luting agents 
260 |b University of São Paulo,   |c 2008-02-01T00:00:00Z. 
500 |a 10.1590/S1678-77572008000100013 
500 |a 1678-7757 
500 |a 1678-7765 
520 |a Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement. 
546 |a EN 
690 |a Dental leakage 
690 |a Dental cements 
690 |a Marginal adaptation 
690 |a Crowns 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 16, Iss 1, Pp 64-69 (2008) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572008000100013 
787 0 |n https://doaj.org/toc/1678-7757 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/04a3cc59b97e45b281a46efbe3c76ac1  |z Connect to this object online.