Jingle bells, what are those smells? Indoor VOC emissions from a live Christmas tree

Every year in the United States conifers are purchased to serve as Christmas trees in homes where they emit volatile organic compounds (VOCs) to the indoor environment. Although many studies have measured the ecosystem-level emissions of VOCs from conifers outdoors (characterizing monoterpene, isopr...

Full description

Saved in:
Bibliographic Details
Main Authors: Dustin Poppendieck (Author), Rileigh Robertson (Author), Michael F. Link (Author)
Format: Book
Published: Elsevier, 2024-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_051848a8c2fe489eb0eae207d30cd9e9
042 |a dc 
100 1 0 |a Dustin Poppendieck  |e author 
700 1 0 |a Rileigh Robertson  |e author 
700 1 0 |a Michael F. Link  |e author 
245 0 0 |a Jingle bells, what are those smells? Indoor VOC emissions from a live Christmas tree 
260 |b Elsevier,   |c 2024-03-01T00:00:00Z. 
500 |a 2950-3620 
500 |a 10.1016/j.indenv.2023.100002 
520 |a Every year in the United States conifers are purchased to serve as Christmas trees in homes where they emit volatile organic compounds (VOCs) to the indoor environment. Although many studies have measured the ecosystem-level emissions of VOCs from conifers outdoors (characterizing monoterpene, isoprene, and aldehyde emissions), little is known about VOC emission rates once a conifer is brought indoors. Using a proton transfer reaction-mass spectrometer we characterized the VOCs emitted from a freshly cut Douglas Fir for 17 days in an environmentally controlled chamber. Ozone injections were also performed to analyze indoor chemistry that may occur. Introduction of the tree into the chamber increased the response of 52 mass spectra signals detected by the PTR-MS by at least 500 counts per second (cps) compared to background levels, with concentrations sharply decreasing after the first two days. Monoterpenes were emitted from the tree at a rate of 12.4 mg h−1 the first day and fell to 1 mg h−1 by day three. Overall, monoterpene emissions from this Douglas fir were initially comparable to other strong indoor monoterpene sources (fragranced products and air fresheners) but decayed quickly and, within days, were smaller than other common indoor sources. Addition of ozone to the chamber resulted in decreased monoterpene concentrations that coincided with modest increases in formaldehyde. Four other emitted VOCs were tentatively identified due to their large increase within the first few hours of the tree placed in the chamber, behavior during ozonation, or pattern of accumulation over time. 
546 |a EN 
690 |a Christmas Trees 
690 |a Monoterpenes 
690 |a Emissions 
690 |a Formaldehyde 
690 |a Public aspects of medicine 
690 |a RA1-1270 
690 |a Building construction 
690 |a TH1-9745 
655 7 |a article  |2 local 
786 0 |n Indoor Environments, Vol 1, Iss 1, Pp 100002- (2024) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S2950362023000024 
787 0 |n https://doaj.org/toc/2950-3620 
856 4 1 |u https://doaj.org/article/051848a8c2fe489eb0eae207d30cd9e9  |z Connect to this object online.