Can Er:YAG laser be an alternative to conventional methods for repairing composite resins?

Abstract Objective: The aim of this study was to compare the effect of four different surface treatments on the repair bond strength of aged composite resin by employing the micro-shear test. Materials and Method: Forty-eight composite blocks were prepared. All samples were thermocycled for 1000 cyc...

Full description

Saved in:
Bibliographic Details
Main Authors: Digdem Eren (Author), Özden Bektaş (Author), Şeyda Siso (Author)
Format: Book
Published: Cumhuriyet University, 2013-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_05e65656b9ec4611a75a6d90682802c0
042 |a dc 
100 1 0 |a Digdem Eren  |e author 
700 1 0 |a Özden Bektaş  |e author 
700 1 0 |a Şeyda Siso  |e author 
245 0 0 |a Can Er:YAG laser be an alternative to conventional methods for repairing composite resins? 
260 |b Cumhuriyet University,   |c 2013-05-01T00:00:00Z. 
500 |a 1302-5805 
500 |a 2146-2852 
500 |a 10.7126/cdj.2013.1787 
520 |a Abstract Objective: The aim of this study was to compare the effect of four different surface treatments on the repair bond strength of aged composite resin by employing the micro-shear test. Materials and Method: Forty-eight composite blocks were prepared. All samples were thermocycled for 1000 cycles between (5±2) and (55±2) ◦C with a dwell time of 30 s and a transfer time of 5 s. The samples were randomly divided into four groups and were subjected to the following treatments (n=12): Group 1 - phosphoric acid; Group 2 - diamond bur ; Group 3 - diamond bur+ phosphoric acid; Group 4 - Er:YAG Laser. After the aging procedure, fresh microhybrid resin composite was bonded to the treated surfaces with an etch and rinse adhesive resin. The repair bond strength of each sample was determined using a micro-shear bond strength test. All data were analyzed using the Kruskal Wallis test. Results: There were no significant differences among samples in the four groups. Conclusion: Based on the results of this study, each of the four surface treatment methods produced sufficient repair bond strength. Clinical Relevance: A proper bonding must be created between the existing aged composite and the new one for successful repair. Key Words: Repair bond strength, composite resin, Er:YAG laser, micro-shear 
546 |a EN 
690 |a repair bond strength 
690 |a  composite resin 
690 |a  er:yag laser 
690 |a  micro-shear 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Cumhuriyet Dental Journal, Vol 16, Iss 2, Pp 125-132 (2013) 
787 0 |n https://dergipark.org.tr/tr/download/article-file/48371 
787 0 |n https://doaj.org/toc/1302-5805 
787 0 |n https://doaj.org/toc/2146-2852 
856 4 1 |u https://doaj.org/article/05e65656b9ec4611a75a6d90682802c0  |z Connect to this object online.