Development and validation of HPLC method for analysis of indolocarbazole derivative LCS-1269

Indolocarbazole glycosidic derivative LCS-1269 with significant antiproliferative activity has been synthesized in N.N. Blokhin National Medical Research Center of Oncology. To control the quality of the substance, the chromatographic method of the assay was created and validated. The technique was...

Full description

Saved in:
Bibliographic Details
Main Authors: Zoya Shprakh (Author), Andrei Budko (Author), Dmitry Kozin (Author), Lydia Ektova (Author), Dmitry Gusev (Author), Vladimir Reshetnyak (Author), Olga Nesterova (Author)
Format: Book
Published: Pensoft Publishers, 2021-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_061ee92c444b47e0b79a1b7f90c9482c
042 |a dc 
100 1 0 |a Zoya Shprakh  |e author 
700 1 0 |a Andrei Budko  |e author 
700 1 0 |a Dmitry Kozin  |e author 
700 1 0 |a Lydia Ektova  |e author 
700 1 0 |a Dmitry Gusev  |e author 
700 1 0 |a Vladimir Reshetnyak  |e author 
700 1 0 |a Olga Nesterova  |e author 
245 0 0 |a Development and validation of HPLC method for analysis of indolocarbazole derivative LCS-1269 
260 |b Pensoft Publishers,   |c 2021-05-01T00:00:00Z. 
500 |a 10.3897/pharmacia.68.e63457 
500 |a 2603-557X 
520 |a Indolocarbazole glycosidic derivative LCS-1269 with significant antiproliferative activity has been synthesized in N.N. Blokhin National Medical Research Center of Oncology. To control the quality of the substance, the chromatographic method of the assay was created and validated. The technique was carried out in a gradient mode using mobile phases consist of acetonitrile, trifluoroacetic acid and purified water. The specificity of the method was shown by checking of test solutions and the special solvent chromatograms. The method linearity was confirmed, and the parameters of linear dependence have been estimated, and the relationship was described by the equation: y = 49.23× - 35.51 with correlation coefficient 0.9998. The method's precision was determined as the repeatability with a relative error of the mean 1.49% and was 2.433 ± 0.036. Was shown, that the results obtained in the intermediate precision estimation were not burdened with a systematic error. The detection limit and quantitation limit were calculated based on the linear relationship data as 3.15 μg/mL and 9.57 μg/mL, respectively. Sensitive HPLC method for LCS-1269 assay in substance has been developed and validated. 
546 |a EN 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Pharmacia, Vol 68, Iss 2, Pp 427-431 (2021) 
787 0 |n https://pharmacia.pensoft.net/article/63457/download/pdf/ 
787 0 |n https://pharmacia.pensoft.net/article/63457/download/xml/ 
787 0 |n https://pharmacia.pensoft.net/article/63457/ 
787 0 |n https://doaj.org/toc/2603-557X 
856 4 1 |u https://doaj.org/article/061ee92c444b47e0b79a1b7f90c9482c  |z Connect to this object online.