El uso de fotocélulas de haz simple y doble para medir la velocidad en carreras®. The use of single- and dual-beam photocells to measure the sprint time®.
Resuemn<p align="justify">El objetivo del estudio fue analizar la influencia de la tecnología de las fotocélulas en el registro de tiempo y su fiabilidad durante de carreras de velocidad de corta distancia. Participaron 25 estudiantes (20.5±0.5 años; 1.78±0.02 m; 77.5±1.8 kg) que...
Kaydedildi:
Asıl Yazarlar: | , , , , , |
---|---|
Materyal Türü: | Kitap |
Baskı/Yayın Bilgisi: |
Ramón Cantó Alcaraz,
2012-10-01T00:00:00Z.
|
Konular: | |
Online Erişim: | Connect to this object online. |
Etiketler: |
Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_078c4c5f540640d89cde0d8d0652cbd4 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Juan García-López |e author |
700 | 1 | 0 | |a Juan Carlos Morante |e author |
700 | 1 | 0 | |a Ana Carmen Ogueta-Alday |e author |
700 | 1 | 0 | |a Javier González-Lázaro |e author |
700 | 1 | 0 | |a José Antonio Rodríguez-Marroyo |e author |
700 | 1 | 0 | |a Gerardo Villa |e author |
245 | 0 | 0 | |a El uso de fotocélulas de haz simple y doble para medir la velocidad en carreras®. The use of single- and dual-beam photocells to measure the sprint time®. |
260 | |b Ramón Cantó Alcaraz, |c 2012-10-01T00:00:00Z. | ||
500 | |a 1885-3137 | ||
520 | |a Resuemn<p align="justify">El objetivo del estudio fue analizar la influencia de la tecnología de las fotocélulas en el registro de tiempo y su fiabilidad durante de carreras de velocidad de corta distancia. Participaron 25 estudiantes (20.5±0.5 años; 1.78±0.02 m; 77.5±1.8 kg) que fueron evaluados en 3 días (2 de familiarización y 1 de test). Se registraron aleatoriamente 3 carreras de aceleración y 3 velocidad lanzada, cronometradas simultáneamente a los 5, 10 y 15 m por dos sistemas de fotocélulas DSD Laser System®: haz simple y doble haz. El tipo de fotocélulas utilizadas influyó en el tiempo de carrera (F=11.92 y p<0.001) y su fiabilidad (F=14.52 y p<0.001). En la carrera de aceleración el haz simple sobrestimó ~0.02 s el tiempo respecto al doble haz (F=42.95 y p<0.001), obteniéndose registros fiables (CCI > 0.80) a los 10 y 5 m, respectivamente. En la carrera lanzada ambos sistemas midieron prácticamente igual (diferencias de ~0.005 s), obteniendo registros fiables a los 15 y 10 m, respectivamente. En conclusión, en carreras de aceleración la distancia mínima a registrar con haz simple debe ser de 10 m, y de 5 m con haz doble, mientras que en carreras lanzadas deberían utilizarse unas distancias mínimas de 15 y 10 m, respectivamente. Futuros estudios deberían analizar la distancia óptima a la primera fotocélula en las carreras de aceleración, para aumentar la fiabilidad de la medición y facilitar la comparación entre registros de diferentes estudios.</p>Abstract<p align="justify">The purpose was to analyze the influence of the timing gates' technology on both running time performance and its reliability during short sprint distances. Twenty-five physical students participated (20.5±0.5 yr; 1.78±0.02 m; 77.5±1.8 kg), whose were evaluated during 3 separate days (2 familiarization sessions and 1 testing session). Three standing-start and 3 flying-start runs were randomized and simultaneously registered at 5, 10 and 15 m by two timing gates DSD Laser System®: single- and dual-beam. The type of timing gates affected the performance (F=11.92 y p<0.001) and the reliability (F=14.52 y p<0.001). During the standing-start runs, the single-beam system overestimated (~0.02 s) the performance with respect to the dual-beam one (F=42.95 y p<0.001), and the reliability was acceptable (CCI>0.80) at the distances of 10 and 5 m, respectively. During the flying-start runs, both systems obtained a very similar registry (differences of ~0.005 s), and the reliability was acceptable at the distances of 15 and 10 m, respectively. In conclusion, during the standing-start runs the minimum distance to registry the performance with a single-beam system should be 10 m, and 5 m with a dual-beam system. During the flying-start runs these distances should be 15 and 10 m, respectively. Further studies should analyze the optimal distance to the first timing gate during the standing-start runs, in order to improve the reliability and to compare the performances which were obtained in different studies.</p> | ||
546 | |a EN | ||
546 | |a ES | ||
690 | |a fotocélulas | ||
690 | |a carreras de velocidad | ||
690 | |a aceleración | ||
690 | |a fiabilidad | ||
690 | |a timing gates | ||
690 | |a sprint | ||
690 | |a standing-start runs | ||
690 | |a reliability. | ||
690 | |a Geography. Anthropology. Recreation | ||
690 | |a G | ||
690 | |a Recreation. Leisure | ||
690 | |a GV1-1860 | ||
690 | |a Sports | ||
690 | |a GV557-1198.995 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Revista Internacional de Ciencias del Deporte, Vol 8, Iss 30, Pp 324-333 (2012) | |
787 | 0 | |n http://dx.doi.org/10.5232/ricyde2012.03003 | |
787 | 0 | |n https://doaj.org/toc/1885-3137 | |
856 | 4 | 1 | |u https://doaj.org/article/078c4c5f540640d89cde0d8d0652cbd4 |z Connect to this object online. |