In vitro force delivery of nickel-titanium superelastic archwires in vertical displacement
OBJECTIVE: The purpose of this study was to evaluate the force delivered by different superlastic nickel-titanium wires during vertical displacement, in order to determine whether their stress release meets the criteria for constant and light forces that are usually accredited to these archwires. ME...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Dental Press Editora,
2012-12-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | OBJECTIVE: The purpose of this study was to evaluate the force delivered by different superlastic nickel-titanium wires during vertical displacement, in order to determine whether their stress release meets the criteria for constant and light forces that are usually accredited to these archwires. METHOD: Ten samples of 6 brands of 0.016-in archwires (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) were tested in a complete metal model using Dynalock brackets (3M Unitek™). In the canine position, there was a sliding bracket connected to a pole. This set was related to a load cell of 0.5 kg attached to a universal testing machine (Autograph AG-199kNG, Shimadzu). The crosshead speed was 0.5 mm/min and the maximum displacement was 1.0 mm. The model was submerged in temperature-controlled water. The results were analyzed by ANOVA (p < 0.05), using the software SAS System 8.02, Cry, NC, USA. RESULTS: The TP archwire had the lowest force throughout the test, although the final force was high (277.91 g). The Rocky Mountain archwire had the highest force release (455.41 g). CONCLUSION: The different brands of wires tested in this study failed in delivering low and constant forces as expected from superlastic nickel-titanium wires. The forces were extremely heavy for a vertical tooth movement.<br>OBJETIVO: o objetivo deste estudo foi avaliar a força liberada por diferentes fios de níquel-titânio (NiTi) superelástico em deslocamento vertical, a fim de determinar se a liberação de estresse por esses satisfaz o critério de forças suaves e constantes, geralmente atribuído a tais arcos. MÉTODOS: dez amostras de seis arcos de NiTi superelástico 0,016" de marcas comerciais diferentes (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) foram testados em um modelo metálico usando braquetes Dynalock (3M Unitek). Na região do canino, havia um braquete móvel conectado a uma haste, a qual estava relacionada com uma célula de carga de 0,5kg de uma máquina universal de ensaios (Autograph AG-199kNG, Shimadzu). O deslocamento do conjunto na região do canino foi realizado a uma velocidade constante de 0,5mm/min e o deslocamento máximo foi de 1,0mm. O conjunto foi submerso em água com temperatura controlada a 37ºC. RESULTADOS: os resultados obtidos foram avaliados por ANOVA (p <0,05), usando o software SAS System 8.02, Cry, NC, EUA. O arco da TP apresentou a menor força durante todo o teste, embora a força final tenha sido elevada (277,91g). O fio da Rocky Mountain demonstrou a maior liberação de força (455,41g). CONCLUSÕES: conclui-se que todas as diferentes marcas comerciais testadas nesse estudo falharam em liberar forças baixas e constantes, como é esperado nos fios de níquel-titânio superelástico. As forças foram extremamente pesadas para o movimento vertical de dentes. |
---|---|
Item Description: | 2176-9451 2177-6709 |