Microscopic evaluation of cleaning efficiency of three different Nickel-Titanium rotary instruments

Introduction: This study compared the cleaning efficiency of Mtwo, Race and Medin Nickel-Titanium (NiTi) rotary instruments. Materials and Methods: Sixty mandibular molar mesial roots were selected with angle curvatures between 25-35 degrees and divided into three groups; each containing 20 teeth. C...

Full description

Saved in:
Bibliographic Details
Main Authors: Maryam Bidar (Author), Saeed Moradi (Author), Maryam Forghani (Author), Salma Bidad (Author), Mahtab Azghadi (Author), Shahrzad Rezvani (Author), Shirin Khoynezhad (Author)
Format: Book
Published: Iranian Association of Endodontists; Iranian Center for Endodontic Research, 2010-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_0b7adfb5d0dd4bbf9cfda929fbc02e2d
042 |a dc 
100 1 0 |a Maryam Bidar  |e author 
700 1 0 |a Saeed Moradi  |e author 
700 1 0 |a Maryam Forghani  |e author 
700 1 0 |a Salma Bidad  |e author 
700 1 0 |a Mahtab Azghadi  |e author 
700 1 0 |a Shahrzad Rezvani  |e author 
700 1 0 |a Shirin Khoynezhad  |e author 
245 0 0 |a Microscopic evaluation of cleaning efficiency of three different Nickel-Titanium rotary instruments 
260 |b Iranian Association of Endodontists; Iranian Center for Endodontic Research,   |c 2010-10-01T00:00:00Z. 
500 |a 1735-7497 
500 |a 2008-2746 
520 |a Introduction: This study compared the cleaning efficiency of Mtwo, Race and Medin Nickel-Titanium (NiTi) rotary instruments. Materials and Methods: Sixty mandibular molar mesial roots were selected with angle curvatures between 25-35 degrees and divided into three groups; each containing 20 teeth. Canals were prepared with the rotary files and irrigated with 2.5% NaOCl solution after each instrument. Total of 5mL of normal saline was used as the final rinse; subsequently the canals were dried with paper points. The amount of debris and smear layer in three parts of the root canal walls was evaluated using SEM and the data were analyzed by using the Kruskal-Wallis test and the Mann-Whitney U test. Results: The results for remnant debris in the coronal part of root canals were similar, whereas in the middle third, Mtwo instruments achieved significantly better results compared to Race and Medin instruments. In the apical third of the root canals more debris was created by Race instruments. Conclusion: Overall, Mtwo instruments had greater success in producing clean canals. 
546 |a EN 
690 |a NiTi rotary 
690 |a Root canal preparation 
690 |a Scanning electron microscopy 
690 |a Smear layer 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Iranian Endodontic Journal, Vol 5, Iss 4, Pp 174-180 (2010) 
787 0 |n http://journals.sbmu.ac.ir/index.php/iej/article/view/1730/1716 
787 0 |n https://doaj.org/toc/1735-7497 
787 0 |n https://doaj.org/toc/2008-2746 
856 4 1 |u https://doaj.org/article/0b7adfb5d0dd4bbf9cfda929fbc02e2d  |z Connect to this object online.