INVESTIGATION OF LIGHT INTENSITY OF LIGHT CURING UNITS AFTER DIFFERENT PERIODS OF USE

Quartz-tungsten halogen light curing units (LCUs) have been the main source of light for the polymerization of resin based composites (RBCs) for several decades. Since the beginning of the 20th century, however, their use has been reduced due to the invention and improvement of LED LCUs. Various fac...

Full description

Saved in:
Bibliographic Details
Main Authors: Georgi Georgiev (Author), Tsanka Dikova (Author), Vladimir Panov (Author)
Format: Book
Published: Peytchinski Publishing, 2021-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_0fc44cb9c23e4eb8ab6d482e3f1c7db3
042 |a dc 
100 1 0 |a Georgi Georgiev  |e author 
700 1 0 |a Tsanka Dikova  |e author 
700 1 0 |a Vladimir Panov  |e author 
245 0 0 |a INVESTIGATION OF LIGHT INTENSITY OF LIGHT CURING UNITS AFTER DIFFERENT PERIODS OF USE 
260 |b Peytchinski Publishing,   |c 2021-12-01T00:00:00Z. 
500 |a 10.5272/jimab.2021274.4164 
500 |a 1312-773X 
520 |a Quartz-tungsten halogen light curing units (LCUs) have been the main source of light for the polymerization of resin based composites (RBCs) for several decades. Since the beginning of the 20th century, however, their use has been reduced due to the invention and improvement of LED LCUs. Various factors can cause a decrease in the light intensity of LED LCUs, one of which is diode aging. The aim of the present paper is to study the change in light intensity of LCUs after different periods of intensive use. For this purpose, the light intensity of 94 regularly used LED LCUs aged between 1 and 10 years was measured with a digital radiometer. The devices were used in conventional mode with maximum light intensity. It was found that regardless of the type and model of LCU, there is a direct relationship between the time of use and light intensity - the longer the operation period of a device is and the more used it is, the lower its intensity is. The decrease in light intensity as devices age is different for different models, as well as for different devices of the same model. In the studied LCUs with a 10-year period of use, 77.5% have light intensity lower than the required minimum of 400 mW/cm2, which makes them unusable. It can be concluded that dentists should regularly monitor and measure the light intensity of their LCUs, especially as they age, to ensure the longevity of their restorative procedures. 
546 |a EN 
690 |a light curing units 
690 |a led 
690 |a light intensity 
690 |a period of use 
690 |a Dentistry 
690 |a RK1-715 
690 |a Medicine (General) 
690 |a R5-920 
655 7 |a article  |2 local 
786 0 |n Journal of IMAB, Vol 27, Iss 4, Pp 4164-4169 (2021) 
787 0 |n https://www.journal-imab-bg.org/issues-2021/issue4/2021vol27-issue4-4164-4169.pdf 
787 0 |n https://doaj.org/toc/1312-773X 
856 4 1 |u https://doaj.org/article/0fc44cb9c23e4eb8ab6d482e3f1c7db3  |z Connect to this object online.