Stress and displacement of mini-implants and appliance in Mini-implant Assisted Rapid Palatal Expansion: analysis by finite element method

ABSTRACT Objective: In this study, simulations were performed by the finite element method (FEM) to determine the tension and displacement in mini-implants and in expander appliance during rapid maxillary expansion, by varying the number and location of the mini-implants. Methods: For the computatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Pedro Lima Emmerich OLIVEIRA (Author), Kayque Euclides Moreira SOARES (Author), Rafhael Milanezi de ANDRADE (Author), Gabriel Couto de OLIVEIRA (Author), Matheus Melo PITHON (Author), Mônica Tirre de Souza ARAÚJO (Author), Eduardo Franzotti SANT'ANNA (Author)
Format: Book
Published: Dental Press Editora, 2021-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_105b64a519db4cdd8c824f7fab11aa98
042 |a dc 
100 1 0 |a Pedro Lima Emmerich OLIVEIRA  |e author 
700 1 0 |a Kayque Euclides Moreira SOARES  |e author 
700 1 0 |a Rafhael Milanezi de ANDRADE  |e author 
700 1 0 |a Gabriel Couto de OLIVEIRA  |e author 
700 1 0 |a Matheus Melo PITHON  |e author 
700 1 0 |a Mônica Tirre de Souza ARAÚJO  |e author 
700 1 0 |a Eduardo Franzotti SANT'ANNA  |e author 
245 0 0 |a Stress and displacement of mini-implants and appliance in Mini-implant Assisted Rapid Palatal Expansion: analysis by finite element method 
260 |b Dental Press Editora,   |c 2021-08-01T00:00:00Z. 
500 |a 2177-6709 
500 |a 10.1590/2177-6709.26.4.e21203.oar 
520 |a ABSTRACT Objective: In this study, simulations were performed by the finite element method (FEM) to determine the tension and displacement in mini-implants and in expander appliance during rapid maxillary expansion, by varying the number and location of the mini-implants. Methods: For the computational simulation, a three-dimensional mesh was used for the maxilla, mini-implants and expander appliance. Comparisons were made on six different Mini-implant Assisted Rapid Palatal Expander (MARPE) configurations, by varying the amount and location of mini-implants. A closed suture was design and received two activations of 0.25 mm, and an open suture had a 0.5-mm aperture that received 20 activations, also of 0.25 mm. Results: For the closed suture, the maximum displacement values in the mini-implants were between 0.253 and 0.280 mm, and stress was between 1,348.9 and 2,948.2 MPa; in the expander appliance, the displacement values were between 0.256 and 0.281 mm, and stress was between 738.52 and 1,207.6 MPa. For the open suture, the maximum displacement values in the mini-implants were between 2.57 and 2.79 mm, and stress was between 5,765.3 and 10,366 MPa; in the appliance, the maximum displacements was between 2.53 and 2.89 mm, and stress was between 4,859.7 and 9,157.4 MPa. Conclusions: There were higher stress concentrations in the mini-implant than in the expander arm. In the simulations with a configuration of three mini-implants, stress overload was observed in the isolated mini-implant. Displacements of the mini-implants and arms of the appliance were similar in all simulations. 
546 |a EN 
546 |a PT 
690 |a Palatal expansion technique 
690 |a Finite element method 
690 |a Orthodontic anchorage procedures 
690 |a Orthodontic appliances 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Press Journal of Orthodontics, Vol 26, Iss 4 (2021) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000400300&tlng=en 
787 0 |n https://doaj.org/toc/2177-6709 
856 4 1 |u https://doaj.org/article/105b64a519db4cdd8c824f7fab11aa98  |z Connect to this object online.