Influence of pulp condition on the accuracy of an electronic foramen locator in posterior teeth: an in vivo study

The aim of this study was to assess, in vivo, the accuracy of the NovApex® electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex®was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL w...

Full description

Saved in:
Bibliographic Details
Main Authors: Daniel Renner (Author), Renata Grazziotin-Soares (Author), Giulio Gavini (Author), Fernando Branco Barletta (Author)
Format: Book
Published: Sociedade Brasileira de Pesquisa Odontológica, 2012-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_10edba80ff464bada38531ff1ccc9f7a
042 |a dc 
100 1 0 |a Daniel Renner  |e author 
700 1 0 |a Renata Grazziotin-Soares  |e author 
700 1 0 |a Giulio Gavini  |e author 
700 1 0 |a Fernando Branco Barletta  |e author 
245 0 0 |a Influence of pulp condition on the accuracy of an electronic foramen locator in posterior teeth: an in vivo study 
260 |b Sociedade Brasileira de Pesquisa Odontológica,   |c 2012-04-01T00:00:00Z. 
500 |a 10.1590/S1806-83242012000200004 
500 |a 1806-8324 
520 |a The aim of this study was to assess, in vivo, the accuracy of the NovApex® electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex®was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex® locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex®(a = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex® measurement. Pulp condition had no significant effect on the accuracy of NovApex®. 
546 |a EN 
690 |a Endodontics 
690 |a Tooth Apex 
690 |a Root Canal Therapy 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Brazilian Oral Research, Vol 26, Iss 2, Pp 106-111 (2012) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000200004 
787 0 |n https://doaj.org/toc/1806-8324 
856 4 1 |u https://doaj.org/article/10edba80ff464bada38531ff1ccc9f7a  |z Connect to this object online.