Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible

Abstract Objective To assess the biomechanical effects of different prosthetic/implant configurations and load directions on 3-unit fixed prostheses supported by short dental implants in the posterior mandible using validated 3-D finite element (FE) models. Methods Models represented an atrophic man...

Full beskrivning

Sparad:
Bibliografiska uppgifter
Huvudupphovsmän: Lana Zupancic Cepic (Författare, medförfattare), Martin Frank (Författare, medförfattare), Andreas Reisinger (Författare, medförfattare), Dieter Pahr (Författare, medförfattare), Werner Zechner (Författare, medförfattare), Andreas Schedle (Författare, medförfattare)
Materialtyp: Bok
Publicerad: SpringerOpen, 2022-02-01T00:00:00Z.
Ämnen:
Länkar:Connect to this object online.
Taggar: Lägg till en tagg
Inga taggar, Lägg till första taggen!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_123c37e540834e46b83d2aea99de92f0
042 |a dc 
100 1 0 |a Lana Zupancic Cepic  |e author 
700 1 0 |a Martin Frank  |e author 
700 1 0 |a Andreas Reisinger  |e author 
700 1 0 |a Dieter Pahr  |e author 
700 1 0 |a Werner Zechner  |e author 
700 1 0 |a Andreas Schedle  |e author 
245 0 0 |a Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible 
260 |b SpringerOpen,   |c 2022-02-01T00:00:00Z. 
500 |a 10.1186/s40729-022-00404-8 
500 |a 2198-4034 
520 |a Abstract Objective To assess the biomechanical effects of different prosthetic/implant configurations and load directions on 3-unit fixed prostheses supported by short dental implants in the posterior mandible using validated 3-D finite element (FE) models. Methods Models represented an atrophic mandible, missing the 2nd premolar, 1st and 2nd molars, and rehabilitated with either two short implants (implant length-IL = 8 mm and 4 mm) supporting a 3-unit dental bridge or three short implants (IL = 8 mm, 6 mm and 4 mm) supporting zirconia prosthesis in splinted or single crowns design. Load simulations were performed in ABAQUS (Dassault Systèmes, France) under axial and oblique (30°) force of 100 N to assess the global stiffness and forces within the implant prosthesis. Local stresses within implant/prosthesis system and strain energy density (SED) within surrounding bone were determined and compared between configurations. Results The global stiffness was around 1.5 times higher in splinted configurations vs. single crowns, whereby off-axis loading lead to a decrease of 39%. Splinted prostheses exhibited a better stress distribution than single crowns. Local stresses were larger and distributed over a larger area under oblique loads compared to axial load direction. The forces on each implant in the 2-implant-splinted configurations increased by 25% compared to splinted crowns on 3 implants. Loading of un-splinted configurations resulted in increased local SED magnitude. Conclusion Splinting of adjacent short implants in posterior mandible by the prosthetic restoration has a profound effect on the magnitude and distribution of the local stress peaks in peri-implant regions. Replacing each missing tooth with an implant is recommended, whenever bone supply and costs permit. 
546 |a EN 
690 |a Biomechanics 
690 |a Finite element analysis 
690 |a Short dental implants 
690 |a Fixed implant-supported prostheses 
690 |a Prosthetic design parameters 
690 |a Functional load 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n International Journal of Implant Dentistry, Vol 8, Iss 1, Pp 1-13 (2022) 
787 0 |n https://doi.org/10.1186/s40729-022-00404-8 
787 0 |n https://doaj.org/toc/2198-4034 
856 4 1 |u https://doaj.org/article/123c37e540834e46b83d2aea99de92f0  |z Connect to this object online.