Preferable Anesthetic Conditions for Echocardiographic Determination of Murine Cardiac Function

Ketamine and xylazine are routinely used for measurement of hemodynamics of mice and rats by echocardiography. The anesthetic agents produce low heart rate (HR) in the animals, which may result in misleading data in the hemodynamic profiles of the small animals. The purpose of the present study was...

Full description

Saved in:
Bibliographic Details
Main Authors: Yuji Kawahara (Author), Kouichi Tanonaka (Author), Takuya Daicho (Author), Mikio Nawa (Author), Ryo Oikawa (Author), Yoshihisa Nasa (Author), Satoshi Takeo (Author)
Format: Book
Published: Elsevier, 2005-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1420264b3d6c4e7d9a8f81a9d8e6bc7e
042 |a dc 
100 1 0 |a Yuji Kawahara  |e author 
700 1 0 |a Kouichi Tanonaka  |e author 
700 1 0 |a Takuya Daicho  |e author 
700 1 0 |a Mikio Nawa  |e author 
700 1 0 |a Ryo Oikawa  |e author 
700 1 0 |a Yoshihisa Nasa  |e author 
700 1 0 |a Satoshi Takeo  |e author 
245 0 0 |a Preferable Anesthetic Conditions for Echocardiographic Determination of Murine Cardiac Function 
260 |b Elsevier,   |c 2005-01-01T00:00:00Z. 
500 |a 1347-8613 
500 |a 10.1254/jphs.fp0050343 
520 |a Ketamine and xylazine are routinely used for measurement of hemodynamics of mice and rats by echocardiography. The anesthetic agents produce low heart rate (HR) in the animals, which may result in misleading data in the hemodynamic profiles of the small animals. The purpose of the present study was to select an appropriate anesthetic condition in the evaluation of mouse and rat cardiac function by echocardiography. Echocardiographic measurement was performed in male C57BL6 mice anesthetized with an intraperitoneal injection of 30 or 40 mg/kg pentobarbital (P30 or P40) or a combination of 60 mg/kg ketamine and 6 mg/kg xylazine (KX) and in male Wistar rats with an intraperitoneal injection of 40 or 50 mg/kg pentobarbital (P40 or P50) or a combination of 100 mg/kg ketamine and 10 mg/kg xylazine (KX). Basal HR of P30-anesthetized mice and P40-anesthetized were comparable to those in the conscious state, whereas KX-anesthetized mice and rats were 38% and 74% of those of the conscious animals, respectively. Fractional shortening (FS) and cardiac output index (COI) of the P30-anesthetized mice or the P40-anesthetized rats were greater than those of KX-anesthetized animals. Intraperitoneal injection of dobutamine at 0.3 and 1 mg/kg increased HR, FS, and COI of the P30-anesthetized mice and the P40-anesthetized rats, respectively, whereas the percent responses of these parameters in KX animals were greater than those in pentobarbital-anesthetized ones due to the lower basal values for the cardiac functional parameters. Anesthesia with P30 for the mouse and P40 for the rat rather than ketamine/xylazine may be relevant to the evaluation of cardiac function using echocardiography. Keywords:: anesthesia, blood flow, cardiac function, echocardiography, heart rate 
546 |a EN 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
655 7 |a article  |2 local 
786 0 |n Journal of Pharmacological Sciences, Vol 99, Iss 1, Pp 95-104 (2005) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S1347861319321383 
787 0 |n https://doaj.org/toc/1347-8613 
856 4 1 |u https://doaj.org/article/1420264b3d6c4e7d9a8f81a9d8e6bc7e  |z Connect to this object online.