Effect of pre-flaring and file size on the accuracy of two electronic apex locators

OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxilla...

Full description

Saved in:
Bibliographic Details
Main Authors: Manoel Brito-Júnior (Author), Carla Cristina Camilo (Author), Gil Moreira-Júnior (Author), Jesus Djalma Pecora (Author), Manoel Damião Sousa-Neto (Author)
Format: Book
Published: University of São Paulo, 2012-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1471be14b86b45fba390c6ca53cacf2b
042 |a dc 
100 1 0 |a Manoel Brito-Júnior  |e author 
700 1 0 |a Carla Cristina Camilo  |e author 
700 1 0 |a Gil Moreira-Júnior  |e author 
700 1 0 |a Jesus Djalma Pecora  |e author 
700 1 0 |a Manoel Damião Sousa-Neto  |e author 
245 0 0 |a Effect of pre-flaring and file size on the accuracy of two electronic apex locators 
260 |b University of São Paulo,   |c 2012-10-01T00:00:00Z. 
500 |a 10.1590/S1678-77572012000500008 
500 |a 1678-7757 
500 |a 1678-7765 
520 |a OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size. 
546 |a EN 
690 |a Endodontics 
690 |a Odontometry 
690 |a Root canal preparation 
690 |a Tooth apex 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 20, Iss 5, Pp 538-543 (2012) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572012000500008 
787 0 |n https://doaj.org/toc/1678-7757 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/1471be14b86b45fba390c6ca53cacf2b  |z Connect to this object online.