<b>Characterization of the heart rate curve during a maximum incremental test on a treadmill</b>. DOI: 10.5007/1980-0037.2011v13n4p285

The objective of this study was to analyze the heart rate (HR) profile plotted against incremental workloads (IWL) during a treadmill test using three mathematical models [linear, linear with 2 segments (Lin2), and sigmoidal], and to determine the best model for the identification of the HR threshol...

Full description

Saved in:
Bibliographic Details
Main Authors: Eduardo Marcel Fernandes Nascimento (Author), Adriano Eduardo Lima Silva (Author), Romulo Cassio de Moraes Bertuzzi (Author), Maria Augusta Peduti Dal Molin Kiss (Author), Flavio Oliveira Pires (Author)
Format: Book
Published: Universidade Federal de Santa Catarina, 2011-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1655f5cef07d4a0b81df8c35f19e01a3
042 |a dc 
100 1 0 |a Eduardo Marcel Fernandes Nascimento  |e author 
700 1 0 |a Adriano Eduardo Lima Silva  |e author 
700 1 0 |a Romulo Cassio de Moraes Bertuzzi  |e author 
700 1 0 |a Maria Augusta Peduti Dal Molin Kiss  |e author 
700 1 0 |a Flavio Oliveira Pires  |e author 
245 0 0 |a <b>Characterization of the heart rate curve during a maximum incremental test on a treadmill</b>. DOI: 10.5007/1980-0037.2011v13n4p285 
260 |b Universidade Federal de Santa Catarina,   |c 2011-08-01T00:00:00Z. 
500 |a 1415-8426 
500 |a 1980-0037 
520 |a The objective of this study was to analyze the heart rate (HR) profile plotted against incremental workloads (IWL) during a treadmill test using three mathematical models [linear, linear with 2 segments (Lin2), and sigmoidal], and to determine the best model for the identification of the HR threshold that could be used as a predictor of ventilatory thresholds (VT1 and VT2). Twenty-two men underwent a treadmill incremental test (retest group: n=12) at an initial speed of 5.5 km.h-1, with increments of 0.5 km.h-1 at 1-min intervals until exhaustion. HR and gas exchange were continuously measured and subsequently converted to 5-s and 20-s averages, respectively. The best model was chosen based on residual sum of squares and mean square error. The HR/IWL ratio was better fitted with the Lin2 model in the test and retest groups (p<0.05). The Lin2 model permitted the identification of the HR threshold (Lin2HRDP) in all subjects of the test (164 ± 16.6 bpm; 83.6% HRMAX) and retest groups (162 ± 20.0 bpm; 83.9% HRMAX). Lin2HRDP (9.2 ± 1.3 km.h-1; 67.9% speedMAX) was lower than VT2 (10.6 ± 1.5 km.h-1, 77.3% speedMAX; p<0.05), but did not differ from VT1 (8.4 ± 1.2 km.h-1, 61.6% speedMAX; p>0.05). During a treadmill incremental test, the HR/IWL ratio seems to be better fitted with a Lin2 model, which permits to determine the HR threshold that coincides with VT1. 
546 |a EN 
546 |a PT 
690 |a Boltzmann sigmoidal model 
690 |a Ergometry 
690 |a Exercise test 
690 |a Physical exertion 
690 |a Heart rate. 
690 |a Sports 
690 |a GV557-1198.995 
690 |a Medicine (General) 
690 |a R5-920 
655 7 |a article  |2 local 
786 0 |n Revista Brasileira de Cineantropometria e Desempenho Humano, Vol 13, Iss 4, Pp 285-291 (2011) 
787 0 |n http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n4p285/17902 
787 0 |n https://doaj.org/toc/1415-8426 
787 0 |n https://doaj.org/toc/1980-0037 
856 4 1 |u https://doaj.org/article/1655f5cef07d4a0b81df8c35f19e01a3  |z Connect to this object online.