Outcomes of Intrauterine Device Insertion by Certified Midwives and Obstetric Nurse Practitioners
ABSTRACT Objectives: to evaluate the outcomes of Interval Copper Intrauterine Device (IUD) insertion performed by certified midwives and obstetric nurse practitioners at a Peri-Hospital Birth Center. Methods: a cross-sectional study was conducted involving 75 women who underwent IUD insertion betwee...
Enregistré dans:
Auteurs principaux: | , |
---|---|
Format: | Livre |
Publié: |
Associação Brasileira de Enfermagem,
2023-11-01T00:00:00Z.
|
Sujets: | |
Accès en ligne: | Connect to this object online. |
Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_1733c7f26f184d91a95f85cf345fcae6 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Thalita Vital Botelho |e author |
700 | 1 | 0 | |a Ana Luiza Vilela Borges |e author |
245 | 0 | 0 | |a Outcomes of Intrauterine Device Insertion by Certified Midwives and Obstetric Nurse Practitioners |
260 | |b Associação Brasileira de Enfermagem, |c 2023-11-01T00:00:00Z. | ||
500 | |a 1984-0446 | ||
500 | |a 10.1590/0034-7167-2022-0286 | ||
520 | |a ABSTRACT Objectives: to evaluate the outcomes of Interval Copper Intrauterine Device (IUD) insertion performed by certified midwives and obstetric nurse practitioners at a Peri-Hospital Birth Center. Methods: a cross-sectional study was conducted involving 75 women who underwent IUD insertion between January 2018 and February 2020. Data collection was carried out using medical records and telephone interviews. Results: no instances of uterine perforation were observed. Expulsion rates of the devices were 1.3% within 30 to 45 days of use and 5.3% within the first year of use. The follow-up removal rate was 4.0%. The average pain score reported was 4.2 (SD = 3.3). Among those who continued using the device, 93.1% expressed satisfaction. Conclusions: the findings demonstrate that IUD insertion by certified midwives and obstetric nurse practitioners is a safe procedure, yielding outcomes comparable to those reported in the existing literature. | ||
546 | |a EN | ||
546 | |a ES | ||
546 | |a PT | ||
690 | |a Intrauterine Device | ||
690 | |a Nurse | ||
690 | |a Midwife | ||
690 | |a Contraception | ||
690 | |a Family Planning | ||
690 | |a Nursing | ||
690 | |a RT1-120 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Revista Brasileira de Enfermagem, Vol 76, Iss 5 (2023) | |
787 | 0 | |n http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S0034-71672023000900210&lng=en&tlng=en | |
787 | 0 | |n http://revodonto.bvsalud.org/pdf/reben/v76n5/0034-7167-reben-76-05-e20220286.pdf | |
787 | 0 | |n https://doaj.org/toc/1984-0446 | |
856 | 4 | 1 | |u https://doaj.org/article/1733c7f26f184d91a95f85cf345fcae6 |z Connect to this object online. |