Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+

Abstract Background Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been develop...

Full description

Saved in:
Bibliographic Details
Main Authors: Raphael Knaier (Author), Christoph Höchsmann (Author), Denis Infanger (Author), Timo Hinrichs (Author), Arno Schmidt-Trucksäss (Author)
Format: Book
Published: BMC, 2019-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1b7053d885da4b3abdc3c1757ffb54c0
042 |a dc 
100 1 0 |a Raphael Knaier  |e author 
700 1 0 |a Christoph Höchsmann  |e author 
700 1 0 |a Denis Infanger  |e author 
700 1 0 |a Timo Hinrichs  |e author 
700 1 0 |a Arno Schmidt-Trucksäss  |e author 
245 0 0 |a Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ 
260 |b BMC,   |c 2019-02-01T00:00:00Z. 
500 |a 10.1186/s12889-019-6568-9 
500 |a 1471-2458 
520 |a Abstract Background Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based on data from hip-worn devices only and have not been tested in a free-living setting. The aim of this study was to validate the automatic wear time detection algorithms of one of the most frequently used devices in a free-living setting. Methods Sixty-eight adults wore one ActiGraph GT3X+ accelerometer on the wrist and one on the hip and additionally recorded wear times for each device separately in a diary. Monitoring phase was during three consecutive days in a free-living setting. Wear time was computed by the algorithms of Troiano and Choi and compared to the diary recordings. Results Mean wear time was over 1420 min per day for both devices on all days. Lin's concordance correlation coefficient for the wrist-worn wear time was 0.73 (0.60; 0.82) when comparing the diary with Troiano and 0.78 (0.67; 0.86) when comparing the diary with Choi. For hip-worn devices the respective values were 0.23 (0.13; 0.33) for Troiano and 0.92 (0.88; 0.95) for Choi. Mean and standard deviation values for absolute percentage errors for wrist-worn devices were − 1.3 ± 8.1% in Troiano and 0.9 ± 7.7% in Choi. The respective values for hip-worn devices were − 17.5 ± 10% in Troiano and − 0.8 ± 4.6% in Choi. Conclusions Hip worn devices may be preferred due to their higher accuracy in physical activity measurement. Automatic wear-time detection can show high errors in individuals, but on a group level, type I, type II, and total errors are generally low when the Choi algorithm is used. In a real-life setting and participants with a high compliance, the algorithm by Choi is sufficient to distinguish wear time from non-wear time on a group level. 
546 |a EN 
690 |a Accelerometer 
690 |a Physical activity 
690 |a Free-living 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n BMC Public Health, Vol 19, Iss 1, Pp 1-6 (2019) 
787 0 |n http://link.springer.com/article/10.1186/s12889-019-6568-9 
787 0 |n https://doaj.org/toc/1471-2458 
856 4 1 |u https://doaj.org/article/1b7053d885da4b3abdc3c1757ffb54c0  |z Connect to this object online.