Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy cl...

Full description

Saved in:
Bibliographic Details
Main Authors: Pramita Suwal (Author), Raj Kumar Singh (Author), Ashok Ayer (Author), Deepak Kumar Roy (Author), Roshan Kumar Roy (Author)
Format: Book
Published: Mashhad University of Medical Sciences, 2017-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1cdf58c2031c4c0b8aa9cf893e6c78f3
042 |a dc 
100 1 0 |a Pramita Suwal  |e author 
700 1 0 |a Raj Kumar Singh  |e author 
700 1 0 |a Ashok Ayer  |e author 
700 1 0 |a Deepak Kumar Roy  |e author 
700 1 0 |a Roshan Kumar Roy  |e author 
245 0 0 |a Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients 
260 |b Mashhad University of Medical Sciences,   |c 2017-03-01T00:00:00Z. 
500 |a 2322-4150 
500 |a 2252-0317 
500 |a 10.22038/jdmt.2016.7841 
520 |a Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05). The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05). The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05). Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p 
546 |a EN 
690 |a Dental prosthesis retention 
690 |a Denture base 
690 |a Masticatory efficiency 
690 |a periodontal health of abutment 
690 |a Removable partial denture 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Materials and Techniques, Vol 6, Iss 1, Pp 27-34 (2017) 
787 0 |n http://jdmt.mums.ac.ir/article_7841_e8a2e08f2d0f72b2975d7c1f94fdf074.pdf 
787 0 |n https://doaj.org/toc/2322-4150 
787 0 |n https://doaj.org/toc/2252-0317 
856 4 1 |u https://doaj.org/article/1cdf58c2031c4c0b8aa9cf893e6c78f3  |z Connect to this object online.