Beam hardening artifacts by dental implants: Comparison of cone-beam and 64-slice computed tomography scanners

Background: Cone beam computed tomography (CBCT) is an alternative to a computed tomography (CT) scan, which is appropriate for a wide range of craniomaxillofacial indications. The long-term use of metallic materials in dentistry means that artifacts caused by metallic restorations in the oral cavit...

Full description

Saved in:
Bibliographic Details
Main Authors: Farzad Esmaeili (Author), Masume Johari (Author), Pezhman Haddadi (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2013-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1d01646f50454809a2bc993bdd1e82ff
042 |a dc 
100 1 0 |a Farzad Esmaeili  |e author 
700 1 0 |a Masume Johari  |e author 
700 1 0 |a Pezhman Haddadi  |e author 
245 0 0 |a Beam hardening artifacts by dental implants: Comparison of cone-beam and 64-slice computed tomography scanners 
260 |b Wolters Kluwer Medknow Publications,   |c 2013-01-01T00:00:00Z. 
500 |a 1735-3327 
500 |a 2008-0255 
500 |a 10.4103/1735-3327.115146 
520 |a Background: Cone beam computed tomography (CBCT) is an alternative to a computed tomography (CT) scan, which is appropriate for a wide range of craniomaxillofacial indications. The long-term use of metallic materials in dentistry means that artifacts caused by metallic restorations in the oral cavity should be taken into account when utilizing CBCT and CT scanners. The aim of this study was to quantitatively compare the beam hardening artifacts produced by dental implants between CBCT and a 64-Slice CT scanner. Materials and Methods: In this descriptive study , an implant drilling model similar to the human mandible was used in the present study. The implants (Dentis) were placed in the canine, premolar and molar areas. Three series of scans were provided from the implant areas using Somatom Sensation 64-slice and NewTom VGi (CBCT) CT scanners. Identical images were evaluated by three radiologists. The artifacts in each image were determined based on pre-determined criteria. Kruskal-Wallis test was used to compare mean values; Mann-Whitney U test was used for two-by-two comparisons when there was a statistical significance ( P < 0.05). Results: The images of the two scanners had similar resolutions in axial sections ( P = 0.299). In coronal sections, there were significant differences in the resolutions of the images produced by the two scanners ( P < 0.001), with a higher resolution in the images produced by NewTom VGi scanner. On the whole, there were significant differences between the resolutions of the images produced by the two CT scanners ( P < 0.001), with higher resolution in the images produced by NewTom VGi scanner in comparison to those of Somatom Sensation. Conclusion: Given the high quality of the images produced by NewTom VGi and the lower costs in comparison to CT, the use of the images of this scanner in dental procedures is recommended, especially in patients with extensive restorations, multiple prostheses and previous implants. 
546 |a EN 
690 |a Beam hardening artifacts 
690 |a cone beam computed tomography 
690 |a dental implants 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Research Journal, Vol 10, Iss 3, Pp 376-381 (2013) 
787 0 |n http://www.drjjournal.net/article.asp?issn=1735-3327;year=2013;volume=10;issue=3;spage=376;epage=381;aulast=Esmaeili 
787 0 |n https://doaj.org/toc/1735-3327 
787 0 |n https://doaj.org/toc/2008-0255 
856 4 1 |u https://doaj.org/article/1d01646f50454809a2bc993bdd1e82ff  |z Connect to this object online.