Three-dimensional automated breast ultrasound - a supplemental screening tool

Background. Three-dimensional automated breast ultrasound (ABUS) is an innovative technology that allows global visualization of the breast and eliminates the operator-dependence of hand held ultrasound. Three-projection scanning during ABUS is provided by an ultra-long (15.4 cm) probe with a freque...

Full description

Saved in:
Bibliographic Details
Main Authors: E. A. Busko (Author), V. V. Semiglazov (Author), N. I. Rozhkova (Author), S. K. Dzhahilova (Author), E. R. Akzyanova (Author), P. V. Krivorotko (Author), V. V. Ryazanov (Author), S. S. Bagnenko (Author)
Format: Book
Published: ABV-press, 2024-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1d78841fb3024df292ad86e30a809de8
042 |a dc 
100 1 0 |a E. A. Busko  |e author 
700 1 0 |a V. V. Semiglazov  |e author 
700 1 0 |a N. I. Rozhkova  |e author 
700 1 0 |a S. K. Dzhahilova  |e author 
700 1 0 |a E. R. Akzyanova  |e author 
700 1 0 |a P. V. Krivorotko  |e author 
700 1 0 |a V. V. Ryazanov  |e author 
700 1 0 |a S. S. Bagnenko  |e author 
245 0 0 |a Three-dimensional automated breast ultrasound - a supplemental screening tool 
260 |b ABV-press,   |c 2024-05-01T00:00:00Z. 
500 |a 1994-4098 
500 |a 1999-8627 
500 |a 10.17650/1994-4098-2024-20-1-24-30 
520 |a Background. Three-dimensional automated breast ultrasound (ABUS) is an innovative technology that allows global visualization of the breast and eliminates the operator-dependence of hand held ultrasound. Three-projection scanning during ABUS is provided by an ultra-long (15.4 cm) probe with a frequency of 14-16 MHz, and then the slices are reconstructed on a workstation. At the same time, high-frequency converters create high-resolution images. Through a special coronal projection, ABUS identifies variants of minimal, non-palpable breast cancer, including those with women with high mammographic breast density, which makes it a promising additional (supplemental screening) method of oncomammoscreening.Aim. To assess the use of ABUS as a supplemental screening tool in women with high mammographic breast density.Materials and methods. The study was conducted in 2018 at the N.N. Petrov National Medical Research Oncology Center, Ministry of Health of Russia. As part of the study, 192 women underwent mammography, ABUS, and multiparametric ultrasound (B-mode, color Doppler, elatography) in standard manual mode.Results. In the course of the study, in 192 patients, mammography revealed 42 cases of breast cancer, while using the AUS and manual ultrasound, additionally were identified 9 cases of breast cancer. Also, the ABUS showed high accuracy in assessment of the distribution of breast cancer - multifocal, multicentric and bilateral.Conclusion. ABUS is a promising and highly effective diagnostic method in women with high mammographic breast density, with its advantages and disadvantages, which can be used in combination with mammography as a supplemental screening tool, especially in women at high risk of developing breast cancer. 
546 |a RU 
690 |a breast cancer 
690 |a dense breast 
690 |a automated breast ultrasound 
690 |a mammography 
690 |a supplemental screening 
690 |a Gynecology and obstetrics 
690 |a RG1-991 
655 7 |a article  |2 local 
786 0 |n Опухоли женской репродуктивной системы, Vol 20, Iss 1, Pp 24-30 (2024) 
787 0 |n https://ojrs.abvpress.ru/ojrs/article/view/1204 
787 0 |n https://doaj.org/toc/1994-4098 
787 0 |n https://doaj.org/toc/1999-8627 
856 4 1 |u https://doaj.org/article/1d78841fb3024df292ad86e30a809de8  |z Connect to this object online.