Background: Totally, implantable access ports (TIAPs) are used for long standing venous catheterization. This study was designed to present our experiences of the TIAPs applications and efficacy of Taurolidine-citrate lock solution (TCLS) against catheter-related infections. Materials and Methods: W...

Full description

Saved in:
Bibliographic Details
Main Authors: Emine Ince (Author), Pelin Oğuzkurt (Author), Abdulkerim Temiz (Author), Semire Serin Ezer (Author), Hasan Özkan Gezer (Author), Nalan Yazici (Author), Akgün Hiçsönmez (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2014-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1dc74ee4176048a2b8428df942c9f65d
042 |a dc 
100 1 0 |a Emine Ince  |e author 
700 1 0 |a Pelin Oğuzkurt  |e author 
700 1 0 |a Abdulkerim Temiz  |e author 
700 1 0 |a Semire Serin Ezer  |e author 
700 1 0 |a Hasan Özkan Gezer  |e author 
700 1 0 |a Nalan Yazici  |e author 
700 1 0 |a Akgün Hiçsönmez  |e author 
245 0 0 |a Complications of total implantable access ports and efficacy of Taurolidine-citrate lock solution against catheter-related infections 
260 |b Wolters Kluwer Medknow Publications,   |c 2014-01-01T00:00:00Z. 
500 |a 0189-6725 
500 |a 0974-5998 
500 |a 10.4103/0189-6725.132806 
520 |a Background: Totally, implantable access ports (TIAPs) are used for long standing venous catheterization. This study was designed to present our experiences of the TIAPs applications and efficacy of Taurolidine-citrate lock solution (TCLS) against catheter-related infections. Materials and Methods: We evaluated records of the 108 patients implanted with 112 TIAPs, which had been performed using heparin solution or TCLS between 2005 and 2013. Results: Duration of exposure to TIAPs was 17-2051 days (median: 411 days). The primary diagnoses were solid tumours (n = 57), lymphoma (n = 23), haematologic diseases (n = 23), nephrotic syndrome (n = 4), Hirschsprung disease (n = 1). The right external jugular vein was most frequently used vascular access route (72.3%). Mechanical complications were observed in four cases. TIAPs were removed due to remission in 19 cases and infection in 19 cases. Median time from implantation and to the development of infection was 60 days. Heparin solution had been used for care in 33 ports, whereas heparin and TCLS had been used in 79 ports. Based on statistical comparison, use of TCLS was considered to be an important factor for preventing infection (P = 0.03). Conclusion: We consider that TCLS reduces infection prevalence so TIAPs would be used more extensively and effectively to prevent infections. 
546 |a EN 
690 |a Catheter 
690 |a infection 
690 |a malignancy 
690 |a port 
690 |a Taurolidine-citrate 
690 |a Pediatrics 
690 |a RJ1-570 
690 |a Surgery 
690 |a RD1-811 
655 7 |a article  |2 local 
786 0 |n African Journal of Paediatric Surgery, Vol 11, Iss 2, Pp 138-142 (2014) 
787 0 |n http://www.afrjpaedsurg.org/article.asp?issn=0189-6725;year=2014;volume=11;issue=2;spage=138;epage=142;aulast=Ince 
787 0 |n https://doaj.org/toc/0189-6725 
787 0 |n https://doaj.org/toc/0974-5998 
856 4 1 |u https://doaj.org/article/1dc74ee4176048a2b8428df942c9f65d  |z Connect to this object online.