Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study

Background: Hypertension is a significant global health issue, responsible for approximately 7.5 million deaths annually. Even a modest increase of 5 mm Hg in systolic blood pressure (BP) can elevate the risk of fatal stroke and infarction by about 25%. Hence this study aimed to assess the accuracy...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mahesh D Kurugodiyavar (Autor), Roopakala N (Autor), Kashavva B Andanigoudar (Autor)
Formato: Libro
Publicado: Medsci Publications, 2024-12-01T00:00:00Z.
Materias:
Acceso en línea:Connect to this object online.
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_1e8260c08c724f34b2d707b8866fde0f
042 |a dc 
100 1 0 |a Mahesh D Kurugodiyavar  |e author 
700 1 0 |a Roopakala N  |e author 
700 1 0 |a Kashavva B Andanigoudar  |e author 
245 0 0 |a Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study 
260 |b Medsci Publications,   |c 2024-12-01T00:00:00Z. 
500 |a 10.55489/njcm.151220244689 
500 |a 0976-3325 
500 |a 2229-6816 
520 |a Background: Hypertension is a significant global health issue, responsible for approximately 7.5 million deaths annually. Even a modest increase of 5 mm Hg in systolic blood pressure (BP) can elevate the risk of fatal stroke and infarction by about 25%. Hence this study aimed to assess the accuracy of aneroid and digital sphygmomanometers relative to the mercury sphygmomanometer. Methodology: This community-based cross-sectional study was conducted in the urban slums of old Hubballi among 270 participants aged 30 years and above. Participants were selected using Probability Proportion to Size from 3 wards. Blood pressures were measured with all three sphygmomanometers and Bland Altman plot analysis was done. Results: The results revealed that the mean difference in systolic blood pressure compared to mercury was -0.57 mmHg for the aneroid and -4.63 mmHg for the digital (p <0.05). For diastolic blood pressure, the mean difference was -0.39 mmHg for the aneroid and -3.43 mmHg for the digital (p <0.05). Bland-Altman analysis showed agreement limits of 66.3% for systolic and 75.2% for diastolic blood pressure with the aneroid sphygmomanometer. Conclusion: The aneroid sphygmomanometer provides more reliable BP readings compared to the digital sphygmomanometer for both systolic and diastolic measurements. 
546 |a EN 
690 |a Aneroid sphygmomanometer 
690 |a Bland-Altman plot 
690 |a Blood pressure 
690 |a Digital sphygmomanometer 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n National Journal of Community Medicine, Vol 15, Iss 12 (2024) 
787 0 |n https://njcmindia.com/index.php/file/article/view/4689 
787 0 |n https://doaj.org/toc/0976-3325 
787 0 |n https://doaj.org/toc/2229-6816 
856 4 1 |u https://doaj.org/article/1e8260c08c724f34b2d707b8866fde0f  |z Connect to this object online.