Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study
Background: Hypertension is a significant global health issue, responsible for approximately 7.5 million deaths annually. Even a modest increase of 5 mm Hg in systolic blood pressure (BP) can elevate the risk of fatal stroke and infarction by about 25%. Hence this study aimed to assess the accuracy...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | Libro |
Publicado: |
Medsci Publications,
2024-12-01T00:00:00Z.
|
Materias: | |
Acceso en línea: | Connect to this object online. |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_1e8260c08c724f34b2d707b8866fde0f | ||
042 | |a dc | ||
100 | 1 | 0 | |a Mahesh D Kurugodiyavar |e author |
700 | 1 | 0 | |a Roopakala N |e author |
700 | 1 | 0 | |a Kashavva B Andanigoudar |e author |
245 | 0 | 0 | |a Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study |
260 | |b Medsci Publications, |c 2024-12-01T00:00:00Z. | ||
500 | |a 10.55489/njcm.151220244689 | ||
500 | |a 0976-3325 | ||
500 | |a 2229-6816 | ||
520 | |a Background: Hypertension is a significant global health issue, responsible for approximately 7.5 million deaths annually. Even a modest increase of 5 mm Hg in systolic blood pressure (BP) can elevate the risk of fatal stroke and infarction by about 25%. Hence this study aimed to assess the accuracy of aneroid and digital sphygmomanometers relative to the mercury sphygmomanometer. Methodology: This community-based cross-sectional study was conducted in the urban slums of old Hubballi among 270 participants aged 30 years and above. Participants were selected using Probability Proportion to Size from 3 wards. Blood pressures were measured with all three sphygmomanometers and Bland Altman plot analysis was done. Results: The results revealed that the mean difference in systolic blood pressure compared to mercury was -0.57 mmHg for the aneroid and -4.63 mmHg for the digital (p <0.05). For diastolic blood pressure, the mean difference was -0.39 mmHg for the aneroid and -3.43 mmHg for the digital (p <0.05). Bland-Altman analysis showed agreement limits of 66.3% for systolic and 75.2% for diastolic blood pressure with the aneroid sphygmomanometer. Conclusion: The aneroid sphygmomanometer provides more reliable BP readings compared to the digital sphygmomanometer for both systolic and diastolic measurements. | ||
546 | |a EN | ||
690 | |a Aneroid sphygmomanometer | ||
690 | |a Bland-Altman plot | ||
690 | |a Blood pressure | ||
690 | |a Digital sphygmomanometer | ||
690 | |a Public aspects of medicine | ||
690 | |a RA1-1270 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n National Journal of Community Medicine, Vol 15, Iss 12 (2024) | |
787 | 0 | |n https://njcmindia.com/index.php/file/article/view/4689 | |
787 | 0 | |n https://doaj.org/toc/0976-3325 | |
787 | 0 | |n https://doaj.org/toc/2229-6816 | |
856 | 4 | 1 | |u https://doaj.org/article/1e8260c08c724f34b2d707b8866fde0f |z Connect to this object online. |