Evaluation of the Haemoglobin Colour Scale and comparison with the HemoCue haemoglobin assay
OBJECTIVE: To evaluate the Haemoglobin Colour Scale developed by WHO for estimating haemoglobin concentration and to compare the results obtained using it and the HemoCue assay with those determined using a reference method, the Technicon H3 analyser. METHODS: The Colour Scale and HemoCue assay were...
Saved in:
Main Author: | |
---|---|
Format: | Book |
Published: |
The World Health Organization,
2002-01-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_1f281526be3b45f087dc0cb4622a5a00 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Paddle J.J. |e author |
245 | 0 | 0 | |a Evaluation of the Haemoglobin Colour Scale and comparison with the HemoCue haemoglobin assay |
260 | |b The World Health Organization, |c 2002-01-01T00:00:00Z. | ||
500 | |a 0042-9686 | ||
520 | |a OBJECTIVE: To evaluate the Haemoglobin Colour Scale developed by WHO for estimating haemoglobin concentration and to compare the results obtained using it and the HemoCue assay with those determined using a reference method, the Technicon H3 analyser. METHODS: The Colour Scale and HemoCue assay were used to test 408 blood samples. Subsequently, Bland-Altman plots were determined and the proximity of the test results to those obtained using the reference method was determined. FINDINGS: The mean difference between the Haemoglobin Colour Scale and the reference method was 0.19 g/dl (95% confidence interval: 3.50 g/dl below to 3.11 g/dl above); the corresponding value for the HemoCue assay was 0.50 g/dl (1.16 g/dl below to 0.16 g/dl above). Only 46.08% of the results obtained by means of the Colour Scale were within 1.0 g/dl of the reference method, whereas 95.34% of the HemoCue results fell within this limit; 22.79% of the Colour Scale results but none of the HemoCue results lay more than 2.0 g/dl from the reference method. CONCLUSION: The Haemoglobin Colour Scale test is too inaccurate for general use, particularly if devices such as the HemoCue are available. | ||
546 | |a EN | ||
690 | |a Hemoglobinometry/methods | ||
690 | |a Reference standards | ||
690 | |a Comparative study | ||
690 | |a Developing countries | ||
690 | |a Public aspects of medicine | ||
690 | |a RA1-1270 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Bulletin of the World Health Organization, Vol 80, Iss 10, Pp 813-816 (2002) | |
787 | 0 | |n http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0042-96862002001000010 | |
787 | 0 | |n https://doaj.org/toc/0042-9686 | |
856 | 4 | 1 | |u https://doaj.org/article/1f281526be3b45f087dc0cb4622a5a00 |z Connect to this object online. |