Comparative Evaluation of the Effect of Manufacturing Process on Distortion of Rotary ProFile and Twisted File: An in Vitro SEM Study

Background and aims. The manufacturing process of rotary Ni-Ti file can influence its resistance to fracture. The rotary ProFile (Dentsply-Maillefer, Baillagues, Switzerland) is manufactured by grinding mechanism whereas Twisted File (Sybron Endo, USA) is manufactured with a twisting method. The pur...

Full description

Saved in:
Bibliographic Details
Main Authors: Swati Sharma (Author), Rajendra Kumar Tewari (Author), Surendra Kumar Mishra (Author), Pankaj Kharade (Author)
Format: Book
Published: Tabriz University of Medical Sciences, 2015-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_20d31d82d236467aa75b68a0a725b4df
042 |a dc 
100 1 0 |a Swati Sharma  |e author 
700 1 0 |a Rajendra Kumar Tewari  |e author 
700 1 0 |a Surendra Kumar Mishra  |e author 
700 1 0 |a Pankaj Kharade  |e author 
245 0 0 |a Comparative Evaluation of the Effect of Manufacturing Process on Distortion of Rotary ProFile and Twisted File: An in Vitro SEM Study 
260 |b Tabriz University of Medical Sciences,   |c 2015-12-01T00:00:00Z. 
500 |a 10.15171/joddd.2015.039 
500 |a 2008-210X 
500 |a 2008-2118 
520 |a Background and aims. The manufacturing process of rotary Ni-Ti file can influence its resistance to fracture. The rotary ProFile (Dentsply-Maillefer, Baillagues, Switzerland) is manufactured by grinding mechanism whereas Twisted File (Sybron Endo, USA) is manufactured with a twisting method. The purpose of this study was to comparatively evaluate the effect of manufacturing process on distortion of rotary ProFile and Twisted files using scanning electron microscopy after in vitro use. Materials and methods. Five sets of each type of file were used for this study -rotary ProFile (group A) and Twisted file (group B). Each set was used according to manufacturer's instructions to prepare 5 mesial canals of extracted mandibular molars. The changes in files were observed under a scanning electron microscope at ×18, ×100, ×250 and ×500 magnifications. Observations were classified as intact with no discernible distortion, intact but with unwinding, and fractured. Group A and B were then compared for deformation and fracture using two-proportion z-test. Results. On SEM observation, used rotary ProFile showed microfractures along the machining grooves whereas Twisted file showed crack propagation that was perpendicular to the machining marks. On statistical analysis, no significant difference was found between ProFile and Twisted file for deformation (P=0.642) and fracture (P=0.475). Conclusion. Within the experimental protocol of this study, it was concluded that both ProFile and Twisted files exhibited visible sign of distortion before fracture. But Twisted file gained edge over ProFile because of its manufacture design and unparalleled resistance to breakage. 
546 |a EN 
690 |a Distortion 
690 |a Ni-Ti files 
690 |a ProFile 
690 |a Scanning electron microscope 
690 |a Twisted file 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Research, Dental Clinics, Dental Prospects, Vol 9, Iss 4, Pp 216-220 (2015) 
787 0 |n http://dentistry.tbzmed.ac.ir/joddd/index.php/joddd/article/view/1805/478 
787 0 |n https://doaj.org/toc/2008-210X 
787 0 |n https://doaj.org/toc/2008-2118 
856 4 1 |u https://doaj.org/article/20d31d82d236467aa75b68a0a725b4df  |z Connect to this object online.