Protein losing enteropathy secondary to a pulmonary artery stent

A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE). He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion...

Full description

Saved in:
Bibliographic Details
Main Authors: Narayanswami Sreeram (Author), Uwe Trieschmann (Author), Gerardus Bennink (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2012-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE). He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.
Item Description:0974-2069
10.4103/0974-2069.93712