Optimization of blood pressure measurement practices for pharmacodynamic analyses of tyrosine‐kinase inhibitors

Abstract Blood pressure measurements form a critical component of adverse event monitoring for tyrosine kinase inhibitors, but might also serve as a biomarker for dose titrations. This study explored the impact of various sources of within‐individual variation on blood pressure readings to improve m...

Full description

Saved in:
Bibliographic Details
Main Authors: Maddalena Centanni (Author), Abel Thijs (Author), Ingrid Desar (Author), Mats O. Karlsson (Author), Lena E. Friberg (Author)
Format: Book
Published: Wiley, 2023-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_2518823f7bdf48f0a8ac901bde4ccd45
042 |a dc 
100 1 0 |a Maddalena Centanni  |e author 
700 1 0 |a Abel Thijs  |e author 
700 1 0 |a Ingrid Desar  |e author 
700 1 0 |a Mats O. Karlsson  |e author 
700 1 0 |a Lena E. Friberg  |e author 
245 0 0 |a Optimization of blood pressure measurement practices for pharmacodynamic analyses of tyrosine‐kinase inhibitors 
260 |b Wiley,   |c 2023-01-01T00:00:00Z. 
500 |a 1752-8062 
500 |a 1752-8054 
500 |a 10.1111/cts.13423 
520 |a Abstract Blood pressure measurements form a critical component of adverse event monitoring for tyrosine kinase inhibitors, but might also serve as a biomarker for dose titrations. This study explored the impact of various sources of within‐individual variation on blood pressure readings to improve measurement practices and evaluated the utility for individual‐ and population‐level dose selection. A pharmacokinetic-pharmacodynamic modeling framework was created to describe circadian blood pressure changes, inter‐ and intra‐day variability, changes from dipper to non‐dipper profiles, and the relationship between drug exposure and blood pressure changes over time. The framework was used to quantitatively evaluate the influence of physiological and pharmacological aspects on blood pressure measurements, as well as to compare measurement techniques, including office‐based, home‐based, and ambulatory 24‐h blood pressure readings. Circadian changes, as well as random intra‐day and inter‐day variability, were found to be the largest sources of within‐individual variation in blood pressure. Office‐based and ambulatory 24‐h measurements gave rise to potential bias (>5 mmHg), which was mitigated by model‐based estimations. Our findings suggest that 5-8 consecutive, home‐based, measurements taken at a consistent time around noon, or alternatively within a limited time frame (e.g., 8.00 a.m. to 12.00 p.m. or 12.00 p.m. to 5.00 p.m.), will give rise to the most consistent blood pressure estimates. Blood pressure measurements likely do not represent a sufficiently accurate method for individual‐level dose selection, but may be valuable for population‐level dose identification. A user‐friendly tool has been made available to allow for interactive blood pressure simulations and estimations for the investigated scenarios. 
546 |a EN 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Clinical and Translational Science, Vol 16, Iss 1, Pp 73-84 (2023) 
787 0 |n https://doi.org/10.1111/cts.13423 
787 0 |n https://doaj.org/toc/1752-8054 
787 0 |n https://doaj.org/toc/1752-8062 
856 4 1 |u https://doaj.org/article/2518823f7bdf48f0a8ac901bde4ccd45  |z Connect to this object online.