Development And Validation Of Stability Indicating RP-HPLC Method For Determination Of Ceritinib

A new, simple, specific, accurate and precise RP-HPLC method was developed for determination of Ceritinib. In the present study, stress testing of Ceritinib was carried out according to ICH guidelines Q1A (R2). Ceritinib was subjected to stress conditions of hydrolysis, oxidation, photolysis and neu...

Full description

Saved in:
Bibliographic Details
Main Authors: Vaibhav Suresh Adhao (Author), J. Sharma (Author), M. Thakare (Author)
Format: Book
Published: Universitas Gadjah Mada, 2017-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_26cfbccb5fdf478aa7d14b1f52c938e3
042 |a dc 
100 1 0 |a Vaibhav Suresh Adhao  |e author 
700 1 0 |a J. Sharma  |e author 
700 1 0 |a M. Thakare  |e author 
245 0 0 |a Development And Validation Of Stability Indicating RP-HPLC Method For Determination Of Ceritinib 
260 |b Universitas Gadjah Mada,   |c 2017-10-01T00:00:00Z. 
500 |a http://dx.doi.org/10.14499/indonesianjpharm28iss4pp241 
500 |a 2338-9427 
500 |a 2338-9486 
520 |a A new, simple, specific, accurate and precise RP-HPLC method was developed for determination of Ceritinib. In the present study, stress testing of Ceritinib was carried out according to ICH guidelines Q1A (R2). Ceritinib was subjected to stress conditions of hydrolysis, oxidation, photolysis and neutral decomposition. Extensive degradation was found to occur in acidic, condition. Mild degradation was observed in basic and at thermal conditions. Successful separation of drug from degradation products formed under stress conditions was achieved on a Hypersil BDS C18 column (250 mm × 4.6 mm, 5.0 μ particle size) using acetonitrile: acetate buffer (pH 3.7 ± 0.05) (50:50 v/v), at a flow rate of 1.0 mL/min and column was maintained at 40˚C. Quantification and linearity was achieved at 272 nm over the concentration range of 5 - 100 μg/mL for Ceritinib. The method was validated for specificity, linearity, accuracy, precision, LOD, LOQ and robustness. 
546 |a EN 
690 |a Stability-indicating 
690 |a HPLC 
690 |a Ceritinib 
690 |a Validation 
690 |a Stress Testing 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Indonesian Journal of Pharmacy, Vol 28, Iss 4, Pp 241-248 (2017) 
787 0 |n http://indonesianjpharm.farmasi.ugm.ac.id/index.php/3/article/view/1259/857 
787 0 |n https://doaj.org/toc/2338-9427 
787 0 |n https://doaj.org/toc/2338-9486 
856 4 1 |u https://doaj.org/article/26cfbccb5fdf478aa7d14b1f52c938e3  |z Connect to this object online.