Comparison of peak expiratory flow measurement by Mini-Wright peak flow meter and electronic spirometer in healthy elementary school children

Objective This study aims to compare peak expiratory flow mea- surement by peak flow meter and electronic spirometer in healthy elementary school children. Methods This was a cross-sectional study performed in an el- ementary school near Cipto Mangunkusumo hospital (SDN Pegangsaan 01). The study gro...

Full description

Saved in:
Bibliographic Details
Main Authors: Mardjanis Said (Author), Sudigdo Sastroasmoro (Author), Bambang Supriyatno (Author), Yovita Ananta (Author)
Format: Book
Published: Indonesian Pediatric Society Publishing House, 2016-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_2b1d504340c0450c82207ebf10d041be
042 |a dc 
100 1 0 |a Mardjanis Said  |e author 
700 1 0 |a Sudigdo Sastroasmoro  |e author 
700 1 0 |a Bambang Supriyatno  |e author 
700 1 0 |a Yovita Ananta  |e author 
245 0 0 |a Comparison of peak expiratory flow measurement by Mini-Wright peak flow meter and electronic spirometer in healthy elementary school children 
260 |b Indonesian Pediatric Society Publishing House,   |c 2016-10-01T00:00:00Z. 
500 |a 0030-9311 
500 |a 2338-476X 
500 |a 10.14238/pi44.6.2004.248-52 
520 |a Objective This study aims to compare peak expiratory flow mea- surement by peak flow meter and electronic spirometer in healthy elementary school children. Methods This was a cross-sectional study performed in an el- ementary school near Cipto Mangunkusumo hospital (SDN Pegangsaan 01). The study group consisted of healthy children aged 6-12 year old. Data regarding identity and history of illness was taken in each subject. Routine physical examination was per- formed and recorded. Each subject performed lung function tests by means of electronic spirometer AS-7 as well as by Mini-Wright peak flow meter. The subject should perform a minimum of three maneuvers for each method where only the best result was re- corded. Method comparison test to assess agreement between two methods was employed in this study. Results There were 10 males and 15 females enrolled in this study. None of the subjects currently have any respiratory symptoms and signs. This study found that the mean peak expiratory flow (PEF) by spirometer was 226.8±73.13 L/min while by peak flow meter was 223.0±45.05. Mean difference between spirometer and peak flow meter measurements is 6.2 with standard deviation of 60.82. These values resulted in limits of agreement of -115.44 to +127.84 L/min. Conclusions This study finds disagreement between electronic spirometer and Mini-Wright peak flow meter in measuring peak expiratory flow, therefore these two devices cannot be used interchangeably. Mini-Wright peak flow meter still has a role in home monitoring, but the physician should interpret the results carefully. 
546 |a EN 
690 |a peak expiratory flow 
690 |a Mini-Wright peak flow meter 
690 |a electronic spirometer 
690 |a agreement 
690 |a Medicine 
690 |a R 
690 |a Pediatrics 
690 |a RJ1-570 
655 7 |a article  |2 local 
786 0 |n Paediatrica Indonesiana, Vol 44, Iss 6, Pp 248-52 (2016) 
787 0 |n https://paediatricaindonesiana.org/index.php/paediatrica-indonesiana/article/view/787 
787 0 |n https://doaj.org/toc/0030-9311 
787 0 |n https://doaj.org/toc/2338-476X 
856 4 1 |u https://doaj.org/article/2b1d504340c0450c82207ebf10d041be  |z Connect to this object online.