Validation of Point-of-Care Ultrasound to Measure Perioperative Edema in Infants With Congenital Heart Disease

Purpose: Fluid overload is a common post-operative issue in children following cardiac surgery and is associated with increased morbidity and mortality. There is currently no gold standard for evaluating fluid status. We sought to validate the use of point-of-care ultrasound to measure skin edema in...

Full description

Saved in:
Bibliographic Details
Main Authors: Jessica N. Persson (Author), Jacqueline Holstein (Author), Lori Silveira (Author), Aimee Irons (Author), Taufiek Konrad Rajab (Author), James Jaggers (Author), Mark D. Twite (Author), Carly Scahill (Author), Mary Kohn (Author), Christine Gold (Author), Jesse A. Davidson (Author)
Format: Book
Published: Frontiers Media S.A., 2021-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_2c8f4a8884bd4e64a0a8e2849c44e892
042 |a dc 
100 1 0 |a Jessica N. Persson  |e author 
700 1 0 |a Jessica N. Persson  |e author 
700 1 0 |a Jacqueline Holstein  |e author 
700 1 0 |a Lori Silveira  |e author 
700 1 0 |a Aimee Irons  |e author 
700 1 0 |a Taufiek Konrad Rajab  |e author 
700 1 0 |a Taufiek Konrad Rajab  |e author 
700 1 0 |a James Jaggers  |e author 
700 1 0 |a James Jaggers  |e author 
700 1 0 |a Mark D. Twite  |e author 
700 1 0 |a Carly Scahill  |e author 
700 1 0 |a Carly Scahill  |e author 
700 1 0 |a Mary Kohn  |e author 
700 1 0 |a Christine Gold  |e author 
700 1 0 |a Jesse A. Davidson  |e author 
700 1 0 |a Jesse A. Davidson  |e author 
245 0 0 |a Validation of Point-of-Care Ultrasound to Measure Perioperative Edema in Infants With Congenital Heart Disease 
260 |b Frontiers Media S.A.,   |c 2021-08-01T00:00:00Z. 
500 |a 2296-2360 
500 |a 10.3389/fped.2021.727571 
520 |a Purpose: Fluid overload is a common post-operative issue in children following cardiac surgery and is associated with increased morbidity and mortality. There is currently no gold standard for evaluating fluid status. We sought to validate the use of point-of-care ultrasound to measure skin edema in infants and assess the intra- and inter-user variability.Methods: Prospective cohort study of neonates (≤30 d/o) and infants (31 d/o to 12 m/o) undergoing cardiac surgery and neonatal controls. Skin ultrasound was performed on four body sites at baseline and daily post-operatively through post-operative day (POD) 3. Subcutaneous tissue depth was manually measured. Intra- and inter-user variability was assessed using intraclass correlation coefficient (ICC).Results: Fifty control and 22 surgical subjects underwent skin ultrasound. There was no difference between baseline surgical and control neonates. Subcutaneous tissue increased in neonates starting POD 1 with minimal improvement by POD 3. In infants, this pattern was less pronounced with near resolution by POD 3. Intra-user variability was excellent (ICC 0.95). Inter-user variability was very good (ICC 0.82).Conclusion: Point-of-care skin ultrasound is a reproducible and reliable method to measure subcutaneous tissue in infants with and without congenital heart disease. Acute increases in subcutaneous tissue suggests development of skin edema, consistent with extravascular fluid overload. There is evidence of skin edema starting POD 1 in all subjects with no substantial improvement by POD 3 in neonates. Point-of-care ultrasound could be an objective way to measure extravascular fluid overload in infants. Further research is needed to determine how extravascular fluid overload correlates to clinical outcomes. 
546 |a EN 
690 |a point-of-care ultrasound 
690 |a congenital heart disease 
690 |a fluid overload 
690 |a cardiac surgery 
690 |a edema 
690 |a Pediatrics 
690 |a RJ1-570 
655 7 |a article  |2 local 
786 0 |n Frontiers in Pediatrics, Vol 9 (2021) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fped.2021.727571/full 
787 0 |n https://doaj.org/toc/2296-2360 
856 4 1 |u https://doaj.org/article/2c8f4a8884bd4e64a0a8e2849c44e892  |z Connect to this object online.