The potential of Corona Charged Aerosol Detector for investigation of telmisartan: B-cyclodextrin inclusion complexes

Cyclodextrins (CDs) are widely used in pharmaceutical analysis due to its biodegradability and eco-friendly character. The particular structure of CDs, characterized by hydrophobic cavity, enables the formation of inclusion complexes with variety of organic compounds. As structures lacking chromopho...

Full description

Saved in:
Bibliographic Details
Main Authors: Maljurić Nevena (Author), Golubović Jelena (Author), Otašević Biljana (Author), Krmar Jovana (Author), Zečević Mira (Author), Protić Ana (Author)
Format: Book
Published: Pharmaceutical Association of Serbia, Belgrade, Serbia, 2019-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_2f0bef2d25c341fc9ada9aaf3e9e52c9
042 |a dc 
100 1 0 |a Maljurić Nevena  |e author 
700 1 0 |a Golubović Jelena  |e author 
700 1 0 |a Otašević Biljana  |e author 
700 1 0 |a Krmar Jovana  |e author 
700 1 0 |a Zečević Mira  |e author 
700 1 0 |a Protić Ana  |e author 
245 0 0 |a The potential of Corona Charged Aerosol Detector for investigation of telmisartan: B-cyclodextrin inclusion complexes 
260 |b Pharmaceutical Association of Serbia, Belgrade, Serbia,   |c 2019-01-01T00:00:00Z. 
500 |a 0004-1963 
500 |a 2217-8767 
500 |a 10.5937/arhfarm1901001M 
520 |a Cyclodextrins (CDs) are widely used in pharmaceutical analysis due to its biodegradability and eco-friendly character. The particular structure of CDs, characterized by hydrophobic cavity, enables the formation of inclusion complexes with variety of organic compounds. As structures lacking chromophores, CDs could not be detected by Photodiode Array (PDA) detector and Corona Charged Aerosol Detector (CAD) was introduced as the most appropriate detector for the formed complexes. The aim of the study was to investigate the degree of complexation between telmisartan, used as a model substance, and b-CD. Moreover, the effect of different b-CD concentrations (5-15 mM) and pH of the aqueous part of mobile phase (3-7) on the degree of complexation was also assessed. The intensity of the formed complex appeared to be the highest when 15 mM b-CD was used for the complexation. Also, it was noticed that the increase in peak areas with an increasing b-CD concentration was more evident at pH 7 in comparison with the same trend at lower pH values. The reproducibility of the measurement was confirmed by low relative standard deviation (RSD) of peak areas within five measurements. These findings support the use of HPLC-CAD methods for studying the process of inclusion complexes formation. 
546 |a SR 
690 |a b-cyclodextrin 
690 |a inclusion complex 
690 |a corona charged aerosol detector 
690 |a telmisartan 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Arhiv za farmaciju, Vol 69, Iss 1, Pp 1-14 (2019) 
787 0 |n https://scindeks-clanci.ceon.rs/data/pdf/0004-1963/2019/0004-19631901001M.pdf 
787 0 |n https://doaj.org/toc/0004-1963 
787 0 |n https://doaj.org/toc/2217-8767 
856 4 1 |u https://doaj.org/article/2f0bef2d25c341fc9ada9aaf3e9e52c9  |z Connect to this object online.