Loop connectors in dentogenic diastema
Patients with a missing tooth along with diastema have limited treatment options to restore the edentulous space. The use of a conventional fixed partial denture (FPD) to replace the missing tooth may result in too wide anterior teeth leading to poor esthetics. Loss of anterior teeth with existing d...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Wolters Kluwer Medknow Publications,
2015-01-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_30178d20f7ae465a91ca86f06922f4fc | ||
042 | |a dc | ||
100 | 1 | 0 | |a Sanjna Nayar |e author |
700 | 1 | 0 | |a Raghevendra Jayesh |e author |
700 | 1 | 0 | |a Venkateshwaran |e author |
700 | 1 | 0 | |a V Dinakarsamy |e author |
245 | 0 | 0 | |a Loop connectors in dentogenic diastema |
260 | |b Wolters Kluwer Medknow Publications, |c 2015-01-01T00:00:00Z. | ||
500 | |a 0975-7406 | ||
500 | |a 0976-4879 | ||
500 | |a 10.4103/0975-7406.155956 | ||
520 | |a Patients with a missing tooth along with diastema have limited treatment options to restore the edentulous space. The use of a conventional fixed partial denture (FPD) to replace the missing tooth may result in too wide anterior teeth leading to poor esthetics. Loss of anterior teeth with existing diastema may result in excess space available for pontic. This condition presents great esthetic challenge for prosthodontist. If implant supported prosthesis is not possible because of inadequate bone support, FPD along with loop connector may be a treatment option to maintain the diastema and provide optimal esthetic restoration. Here, we report a clinical case where FPD along with loop connector was used to achieve esthetic rehabilitation in maxillary anterior region in which midline diastema has been maintained. | ||
546 | |a EN | ||
690 | |a Diastema | ||
690 | |a esthetic | ||
690 | |a fixed partial denture | ||
690 | |a loop connector | ||
690 | |a Pharmacy and materia medica | ||
690 | |a RS1-441 | ||
690 | |a Analytical chemistry | ||
690 | |a QD71-142 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Pharmacy and Bioallied Sciences, Vol 7, Iss 5, Pp 279-281 (2015) | |
787 | 0 | |n http://www.jpbsonline.org/article.asp?issn=0975-7406;year=2015;volume=7;issue=5;spage=279;epage=281;aulast=Nayar | |
787 | 0 | |n https://doaj.org/toc/0975-7406 | |
787 | 0 | |n https://doaj.org/toc/0976-4879 | |
856 | 4 | 1 | |u https://doaj.org/article/30178d20f7ae465a91ca86f06922f4fc |z Connect to this object online. |