Effect of an aerosol- reduction device on spreading infected aerosols during ultrasonic scaling

Statement of Problem: Ultrasonic Scaling is one of the main sources of producing infected aerosols in dentistry. These aerosols are able to spread pathogens such as microorganisms associated with tuberculosis, conjunctivitis, influenza and other respiratory diseases, herpetic and other skin diseases...

Full description

Saved in:
Bibliographic Details
Main Authors: Ghalyani Isfahani P. Assistant Professor" (Author), ICeyhan A. Dentist (Author), Shirani A. S (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2003-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_304c7608f0a946ed8898b16415073209
042 |a dc 
100 1 0 |a Ghalyani Isfahani P. Assistant Professor"  |e author 
700 1 0 |a ICeyhan A. Dentist  |e author 
700 1 0 |a Shirani A. S  |e author 
245 0 0 |a Effect of an aerosol- reduction device on spreading infected aerosols during ultrasonic scaling 
260 |b Tehran University of Medical Sciences,   |c 2003-07-01T00:00:00Z. 
500 |a 1024-641X 
500 |a 2008-2444 
520 |a Statement of Problem: Ultrasonic Scaling is one of the main sources of producing infected aerosols in dentistry. These aerosols are able to spread pathogens such as microorganisms associated with tuberculosis, conjunctivitis, influenza and other respiratory diseases, herpetic and other skin diseases, ADIS and hepatitis B."nPurpose: The aim of this study was to investigate the clinical effectiveness of an aerosol- reduction device attaching to ultrasonic scaler handpiece."nMaterials and Methods: In this experimental study 18 patients participated. Randomly, mandibular and maxillary quadrants of one side, in each subject, were scaled using an ultrasonic scaler with aerosol-reduction device for 5 minutes. After 30 minutes, another quadrant was scaled by ultrasonic scaler without aerosol- reduction device. In order to determine the effectiveness of aerosol- reduction device, blood agar plates attached to the surgical mask of the operator, 30 cm far from the patient's mouth, were incubated in 37°c for three days and the colonies were counted. Median, Interquartile eange and Wilcoxon test, at the 0.05 level of significance, were used to analyze the data."nResults: The median and interquartile range for the number of colony forming units (CFUS) without aerosol- reduction device was 17.5 (8, 24), while the median for the number of CFUS when using aerosol-reduction device was 0 (0, 1), indicating significant statistical difference (PO.001) Conclusion: The aerosol- reduction device significantly reduces the amount of aerosols produced during ultrasonic scaling. 
546 |a FA 
690 |a Dental equipment 
690 |a Aerosol 
690 |a Ultrasonic Scaling 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Medicine, Vol 16, Iss 2, Pp 5-10 (2003) 
787 0 |n http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4598.pdf&manuscript_id=4598 
787 0 |n https://doaj.org/toc/1024-641X 
787 0 |n https://doaj.org/toc/2008-2444 
856 4 1 |u https://doaj.org/article/304c7608f0a946ed8898b16415073209  |z Connect to this object online.