Evaluation of Root-End Resections Performed by Er, Cr: YSGG Laser with and without Placement of a Root-End Filling Material

Microleakage following root-end resections has a direct influence on the outcome of surgical endodontic procedures. This study compared the microleakage after root-end resections performed by the Er, Cr: YSGG laser or carbide burs with or without the placement of MTA, and evaluated the presence of m...

Full description

Saved in:
Bibliographic Details
Main Authors: John Sullivan (Author), Roberta Pileggi (Author), Claudio Varella (Author)
Format: Book
Published: Hindawi Limited, 2009-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_32b62d197fc24e0eb767100e85a8dca8
042 |a dc 
100 1 0 |a John Sullivan  |e author 
700 1 0 |a Roberta Pileggi  |e author 
700 1 0 |a Claudio Varella  |e author 
245 0 0 |a Evaluation of Root-End Resections Performed by Er, Cr: YSGG Laser with and without Placement of a Root-End Filling Material 
260 |b Hindawi Limited,   |c 2009-01-01T00:00:00Z. 
500 |a 1687-8728 
500 |a 1687-8736 
500 |a 10.1155/2009/798786 
520 |a Microleakage following root-end resections has a direct influence on the outcome of surgical endodontic procedures. This study compared the microleakage after root-end resections performed by the Er, Cr: YSGG laser or carbide burs with or without the placement of MTA, and evaluated the presence of microcracks and gaps at the interface of GP/MTA and the canal walls. Ninety single-rooted teeth were instrumented, obturated with GP and AH-Plus sealer, and divided into 3 experimental groups: (I) root-end resections were performed with the laser and G6 tips (parameters: 4.5 w, 30 pps, 20% water and 50% air); (II) Lindeman burs were used, without the placement of MTA; (III) the burs were used followed by root-end fillings with MTA, and one control (IV) of five unobturated roots resected with the burs. The samples were prepared for microleakage (=20) and SEM (=10) analysis. They were immersed in 1% methylene blue, decalcified, cleared, and evaluated for dye penetration (mm2) with the ImageJ software. Epoxy-resin replicas of the root-ends were analyzed by SEM for gaps (m2) and microcracks. Microleakage results were 0.518±1.059, 0.172±0.223, and 0.158±0.253, for the laser (I), no root-end filling (II), and MTA (III) samples, respectively, (ANOVA =.02). The laser (7831.7±2329.2) and no root-end filling (7137.3±1400.7) samples presented gaps. Whereas, none was found in the MTA (ANOVA =.002). Microcracks were not observed. The MTA group demonstrated statistically less leakage and better adaptation to the canal walls when compared to the other groups. There was no correlation between the size of the gaps and the degree of microleakage. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n International Journal of Dentistry, Vol 2009 (2009) 
787 0 |n http://dx.doi.org/10.1155/2009/798786 
787 0 |n https://doaj.org/toc/1687-8728 
787 0 |n https://doaj.org/toc/1687-8736 
856 4 1 |u https://doaj.org/article/32b62d197fc24e0eb767100e85a8dca8  |z Connect to this object online.