A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitrostudy

Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). Materials and Methods: A c...

Full description

Saved in:
Bibliographic Details
Main Authors: Bhavya Mohandas Amin (Author), Meena Ajay Aras (Author), Vidya Chitre (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2015-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_33d0dfec850c4cb79c4d14ddf70bb8b5
042 |a dc 
100 1 0 |a Bhavya Mohandas Amin  |e author 
700 1 0 |a Meena Ajay Aras  |e author 
700 1 0 |a Vidya Chitre  |e author 
245 0 0 |a A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitrostudy 
260 |b Wolters Kluwer Medknow Publications,   |c 2015-01-01T00:00:00Z. 
500 |a 0976-237X 
500 |a 0976-2361 
500 |a 10.4103/0976-237X.156035 
520 |a Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83-128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns. 
546 |a EN 
690 |a Crowns 
690 |a marginal accuracy 
690 |a provisional 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Contemporary Clinical Dentistry, Vol 6, Iss 2, Pp 161-165 (2015) 
787 0 |n http://www.contempclindent.org/article.asp?issn=0976-237X;year=2015;volume=6;issue=2;spage=161;epage=165;aulast=Amin 
787 0 |n https://doaj.org/toc/0976-237X 
787 0 |n https://doaj.org/toc/0976-2361 
856 4 1 |u https://doaj.org/article/33d0dfec850c4cb79c4d14ddf70bb8b5  |z Connect to this object online.