Comparison between Portable Pulse Oximeter and Conventional ICU Pulse Oximeter measurements in healthy adults: A Cross Sectional Study

ABSTRACT: Objective: To assess the agreement between oxygen saturation reading between portable pulse oximeter and conventional ICU monitor pulse oximeter. Methods: This cross-sectional study was conducted at Department of Medicine, Fatima Hospital Baqai Medical University, Karachi, from 1st March 2...

Full description

Saved in:
Bibliographic Details
Main Authors: Adil Khan (Author), Bushra Rabbani (Author), Aashir Jameel (Author), Beena Khan (Author), Tahir Husain (Author), Jameel Ahmed (Author)
Format: Book
Published: KARACHI MEDICAL AND DENTAL COLLEGE, 2024-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_3ae3f1e98a19473fab9b9cd17c2b83f4
042 |a dc 
100 1 0 |a Adil Khan  |e author 
700 1 0 |a Bushra Rabbani  |e author 
700 1 0 |a Aashir Jameel  |e author 
700 1 0 |a Beena Khan  |e author 
700 1 0 |a Tahir Husain  |e author 
700 1 0 |a Jameel Ahmed  |e author 
245 0 0 |a Comparison between Portable Pulse Oximeter and Conventional ICU Pulse Oximeter measurements in healthy adults: A Cross Sectional Study 
260 |b KARACHI MEDICAL AND DENTAL COLLEGE,   |c 2024-02-01T00:00:00Z. 
500 |a 1563-3241 
520 |a ABSTRACT: Objective: To assess the agreement between oxygen saturation reading between portable pulse oximeter and conventional ICU monitor pulse oximeter. Methods: This cross-sectional study was conducted at Department of Medicine, Fatima Hospital Baqai Medical University, Karachi, from 1st March 2023 to 31st March 2023. Participants in the study in- cluded healthy health care workers and medical students who were over the age of 18 and did not have any known co-morbid conditions like hypertension or diabetes that may affect peripheral perfu- sion. None of the participants had hypotension, clinical evidence of anemia, fingernail paint or poor peripheral perfusion as these are the factors that may influence pulse oximetry readings. Both the portable pulse oximeter and the traditional intensive care unit (ICU) monitors were utilized to take and record the oxygen saturation levels of each of the ten fingers in a sequential manner while the patient was seated. Data was analyzed using SPSS version 22. Readings of both instruments were com- pared employing Regression analysis. Bland-Altman analysis was applied to measure the level of agreement between readings of portable pulse oximeter and conventional ICU monitors. Results: Total 200 participants were enrolled for this study and most of them were from younger age group. (Mean age of participants = 33.05 ± 10.31). There was no significant difference between oxy- gen saturation readings of respective finger from portable pulse oximeter and conventional ICU moni- tors on regression analysis (p > 0.05). Highest mean oxygen saturation was recorded in right middle finger using portable pulse oximeter (98.71 ± 1.21). On the ICU monitor pulse oximeter, it was 2nd highest in right middle finger (98.33 ± 2.49). Therefore, Bold-Altman analysis applied between oxygen saturation reading for two devices in right middle finger and was found to be comparable. (Mean dif- ference (bias) = 0.375 with 95% confidence interval). Conclusion: Modern portable pulse oximeters can reliably be used to rule out hypoxemia. 
546 |a EN 
690 |a Pulse oximetry 
690 |a Portable pulse oximeter 
690 |a  ICU monitors 
690 |a Oxygen saturation 
690 |a Hypoxemia 
690 |a Medicine (General) 
690 |a R5-920 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Annals of Abbasi Shaheed Hospital and Karachi Medical & Dental College, Vol 29, Iss 1 (2024) 
787 0 |n https://www.annals-ashkmdc.org/index.php/ashkmdc/article/view/794 
787 0 |n https://doaj.org/toc/1563-3241 
856 4 1 |u https://doaj.org/article/3ae3f1e98a19473fab9b9cd17c2b83f4  |z Connect to this object online.