Retention after orthodontic treatment is still an important part of the treatment. Splints are considered as an alternative for removable retainers. The main goal of this study was to assess splinting biomechanically.Three dimensional finite element models (3D) were designed of a mandibular anterior...

Full description

Saved in:
Bibliographic Details
Main Authors: A Geramy (Author), J M Retrouvey (Author), F Sobuti (Author), H Salehi (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2012-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_3d4fa11df99a44048c83779ddb666502
042 |a dc 
100 1 0 |a A Geramy  |e author 
700 1 0 |a J M Retrouvey  |e author 
700 1 0 |a F Sobuti  |e author 
700 1 0 |a H Salehi  |e author 
245 0 0 |a Anterior Teeth Splinting After Orthodontic Treatment: 3D Analysis Using Finite Element Method. 
260 |b Tehran University of Medical Sciences,   |c 2012-06-01T00:00:00Z. 
500 |a 2676-296X 
520 |a Retention after orthodontic treatment is still an important part of the treatment. Splints are considered as an alternative for removable retainers. The main goal of this study was to assess splinting biomechanically.Three dimensional finite element models (3D) were designed of a mandibular anterior segment which included six anterior teeth with their supporting tissues (model 1 as control) and with a bonded lingual fixed retainer in the two other models. The wire cross section was round (0.016") in model 2 and rectangular (0.016" × 0.022") in model 3. The models were designed in Solid Works 2006 and analyzed in ANSYS Workbench Ver. 11.0 SolidWorks Incisors were loaded with a vertical force of 187 N. PDL stress and tooth displacements were evaluated.The numeric findings showed an increase after splinting in the central incisors [2.42 MPa to 4.57 MPa (round) and 16.66 (rectangular) MPa] in biting with four incisors. Biting with two incisors decreased the stress after splinting [2.42 MPa to 1.7 MPa (round wire) and 1.77 MPa (rectangular wire)]. In lateral movement, all teeth showed an increased stress except for the working side canine.Splinted cases (with round or rectangular wires) can benefit from stress redistribution when biting small food particles and in lateral movement. 
546 |a EN 
690 |a Finite element method 
690 |a Lower Anterior Teeth 
690 |a Orthodontic Treatment 
690 |a Retention 
690 |a Splinting 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Frontiers in Dentistry, Vol 9, Iss 2 (2012) 
787 0 |n https://jdt.tums.ac.ir/index.php/jdt/article/view/779 
787 0 |n https://doaj.org/toc/2676-296X 
856 4 1 |u https://doaj.org/article/3d4fa11df99a44048c83779ddb666502  |z Connect to this object online.