Apical debris extrusion of single-file systems in curved canals

Objectives: The aim of this study was to compare the apical debris extrusion after using three different single-file systems. Materials and Methods: Mesial roots with curved canals of extracted mandibular molar teeth were randomly divided into three experimental groups according to preparation techn...

Full description

Saved in:
Bibliographic Details
Main Authors: Ecehan Hazar (Author), Olcay Özdemir (Author), Mustafa Murat Koçak (Author), Baran Can Sağlam (Author), Sibel Koçak (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2021-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_3d5a3793110c49dd9ba43e7f42d6d2fa
042 |a dc 
100 1 0 |a Ecehan Hazar  |e author 
700 1 0 |a Olcay Özdemir  |e author 
700 1 0 |a Mustafa Murat Koçak  |e author 
700 1 0 |a Baran Can Sağlam  |e author 
700 1 0 |a Sibel Koçak  |e author 
245 0 0 |a Apical debris extrusion of single-file systems in curved canals 
260 |b Wolters Kluwer Medknow Publications,   |c 2021-01-01T00:00:00Z. 
500 |a 0970-7212 
500 |a 10.4103/endo.endo_105_21 
520 |a Objectives: The aim of this study was to compare the apical debris extrusion after using three different single-file systems. Materials and Methods: Mesial roots with curved canals of extracted mandibular molar teeth were randomly divided into three experimental groups according to preparation techniques: the XP-endo Shaper, WaveOne Gold, and One Curve. Previously weighed Eppendorf tubes were used to collect the debris which was placed in a 35°C hot water bath. The weight of the empty tube was subtracted from the final weight after instrumentation and recorded as the amount of extruded debris. The data were analyzed using the Kruskal-Wallis test at a 5% level of significance and compared all groups. Results: XP-endo Shaper presented less debris extrusion than WaveOne Gold and One Curve (P < 0.05). There was no significant difference between the WaveOne Gold and the One Curve files (P > 0.05). Conclusions: All the tested file systems caused debris extrusion. XP-endo Shaper caused less debris extrusion than WaveOne Gold and One Curve files. 
546 |a EN 
690 |a dental instruments 
690 |a nickel-titanium 
690 |a root canal preparation 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Endodontology, Vol 33, Iss 3, Pp 128-132 (2021) 
787 0 |n http://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2021;volume=33;issue=3;spage=128;epage=132;aulast=Hazar 
787 0 |n https://doaj.org/toc/0970-7212 
856 4 1 |u https://doaj.org/article/3d5a3793110c49dd9ba43e7f42d6d2fa  |z Connect to this object online.