The Quality Control Program for Industrial Hygiene Laboratories in Korea

In 1992, the quality control program was introduced in Republic of Korea to improve the reliability of the work environment monitoring, which was introduced in the 1980s. The commission entrusted by the Ministry of Employment and Labor, the Occupational Safety and Health Research Institute has condu...

Full description

Saved in:
Bibliographic Details
Main Authors: Hae Dong Park (Author), Eun Kyo Chung (Author), Kiwoong Kim (Author)
Format: Book
Published: Elsevier, 2017-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_40b39d639d0045b48adba5288dcb821a
042 |a dc 
100 1 0 |a Hae Dong Park  |e author 
700 1 0 |a Eun Kyo Chung  |e author 
700 1 0 |a Kiwoong Kim  |e author 
245 0 0 |a The Quality Control Program for Industrial Hygiene Laboratories in Korea 
260 |b Elsevier,   |c 2017-09-01T00:00:00Z. 
500 |a 2093-7911 
500 |a 10.1016/j.shaw.2017.08.003 
520 |a In 1992, the quality control program was introduced in Republic of Korea to improve the reliability of the work environment monitoring, which was introduced in the 1980s. The commission entrusted by the Ministry of Employment and Labor, the Occupational Safety and Health Research Institute has conducted the program for industrial hygiene laboratories including designated monitoring institutions and spontaneously participating agencies. The number of institutions that participated in the program has increased from 30 to 161. The initial conformance ratio in the participants was 43% (organic solvents) and 52% (metals). Thereafter, the conformance ratio increased rapidly and it has remained in a stable state at more than 89% since 1996. As subject materials, 13 kinds of organic solvents and 7 kinds of metals were used. To improve the capability of measurement and analysis of private institutions, educational courses were conducted annually. An assessment at the actual sites of participants was additionally introduced into the program in 2013. Thus, the program turned into a system that administrates the overall process of participants. For the future, the scope of target materials will be extended through additional items. Thus, the reliability of the results of the work environment monitoring is expected to increase accordingly. 
546 |a EN 
690 |a proficiency analytical testing 
690 |a quality control 
690 |a work environmental monitoring 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Safety and Health at Work, Vol 8, Iss 3, Pp 322-326 (2017) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S2093791117303128 
787 0 |n https://doaj.org/toc/2093-7911 
856 4 1 |u https://doaj.org/article/40b39d639d0045b48adba5288dcb821a  |z Connect to this object online.